Concluding Steps; Replacing The Tpm; Preliminary Steps - Fujitsu PRIMERGY RX300 S8 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX300 S8:
Table of Contents

14.4.2.3 Concluding steps

"Installing the fan box" on page 164
Ê
"Reassembling" on page 63
Ê
"Connecting the server to the power source" on page 69
Ê
"Switching on the server" on page 71
Ê

14.4.3 Replacing the TPM

Field Replaceable Unit
(FRU)
Tools: Removing the system board:
– Phillips PH2 / (+) No. 2 screw driver
Replacing the TPM:
– Bit screw driver
– TPM bit insert
– thin slotted screw driver (2 x 0.4 mm)
(
)
*
For the Japanese market:
– Dedicated TPM screw driver (CWZ8291A)
– TPM module fixing tool (S26361-F3552-L909)
V
CAUTION!
Advise your contact persons that they must provide you with TPM
backup copies. For security reasons, the TPM must be restored/re-
saved by the customer. After installing a new system board, the TPM
must be enabled. You may not clear the TPM data.
If the contact persons DO NOT have a backup copy available, inform
them that replacing the TPM will cause to lose all data.

14.4.3.1 Preliminary steps

"Disabling BitLocker functionality" on page 73
Ê
RX300 S8
(
)
*
Upgrade and Maintenance Manual
System board and components
Hardware: 40 minutes
(
)
*
423
Table of Contents
loading