Emerson Dixell XWEB300 Installation Manual

Hide thumbs Also See for Dixell XWEB300:
INSTALLATION
GUIDE
(v. 2.1)
Table of Contents
loading

Summary of Contents for Emerson Dixell XWEB300

  • Page 1 INSTALLATION GUIDE (v. 2.1)
  • Page 3 < Read carefully before proceeding with the lecture of this manual > WARNING: Use only modems supported by this monitoring unit. Dixell S.r.l. can accept no responsibility for possible damage due the usage of not supported modems. WARNING: Dixell S.r.l. reserves itself the right to alter this manual without notice.
  • Page 4: Table Of Contents

    Contents CHECK LIST ....................5 RS485 CONNECTION ................6 The TTL output ..................8 Serial address of the instruments ............. 8 MODEM CONNECTION (“or point to point connection”)......9 INTRANET/ETHERNET CONNECTION ............19 INTERNET CONNECTION................. 20 TROUBLESHOOTING GUIDE ..............22 UNIT SETUP REMINDER ................
  • Page 5: Check List

    1. CHECK LIST Before opening package please check it to be intact and tit does not show crashes or alteration marks. In the packaging you shall find: XWEB [1].  CD Rom with manual and accessory softwares [2].  Power cord [3] ...
  • Page 6: Rs485 Connection

    2. RS485 CONNECTION To be connected to the serial line all the Dixell Modbus instruments must be provided with direct RS485 terminals or the “TTL”-RS485 interface (XJRS485 or XJ485). Check the instrument manuals for more information. The RS485 line is mainly based on two polarised terminals.
  • Page 7 Wrong connection Always keep the serial cable away from power cables. Always keep the serial cable away from Electro-magnetic or frequency sources. Do not connect shield to ground. Do not connect the “Gnd (ground)” terminal. Remember to draw a map of the line. This will help you to find errors if something is wrong.
  • Page 8: The Ttl Output

    The TTL output The instrument with RS485 on board does not need any kind of external interface module. For instruments with an external interface: keep the TTL cable away from power cables or frequency sources. The XJ485 external interface must be connected with a TTL cable to the instrument with TTL compatibility.
  • Page 9: Modem Connection ("Or Point To Point Connection")

    3. MODEM CONNECTION (“or point to point connection”) It represents the most common method where the LAN (intranet / Ethernet / internet) is not available. It is strongly advised to use a dedicated telephone line. IMPORTANT: Use exclusively modem devices approved by Dixell. Remember that many modems are not compatible with Linux.
  • Page 10 1592028150 XWEB300D_500_500D stp GB r2.1 2012.06.22.doc XWEB500 10/23...
  • Page 11 2. If Control Panel is set for "Classic View", double-click on the Network Connections icon. 3. If Control Panel is set for "Category View", select the "Network and Internet Connections" category, then double-click on the Network Connections icon. 1592028150 XWEB300D_500_500D stp GB r2.1 2012.06.22.doc XWEB500 11/23...
  • Page 12 4. Under Network Tasks, select "Create a new connection". 1592028150 XWEB300D_500_500D stp GB r2.1 2012.06.22.doc XWEB500 12/23...
  • Page 13 5. Click "Next". 1592028150 XWEB300D_500_500D stp GB r2.1 2012.06.22.doc XWEB500 13/23...
  • Page 14 6. Click "Next" at the bottom of this page to continue with the setup instructions. 7. Select "Connect to the Internet" and click "Next". 8. Select "Set up my connection manually" and click "Next". 1592028150 XWEB300D_500_500D stp GB r2.1 2012.06.22.doc XWEB500 14/23...
  • Page 15 9. Select "Connect using a dialup modem" and click "Next". 10. Type "XWEB 500 DIRECT MODEM" in the ISP Name box and click "Next". 1592028150 XWEB300D_500_500D stp GB r2.1 2012.06.22.doc XWEB500 15/23...
  • Page 16 Type access number Phone Number box. E.G: If telephone number is 555789 and area code is 099, put this Telephone number: 099555789. If there is a switching machine and you have to dial a digit to get the line ( 0 or 9 for example, it depends on the switching machine), put this telephone number: 0,099555789 or 9,099555789.
  • Page 17 12. Type dialup account name dixell in the User Name box. Type dialup password dixell in the Password and Confirm Password boxes. We recommend that you check the first 2 checkboxes, but not the 3rd box which turns on the Internet Connection Firewall.
  • Page 18 14. You are now ready to connect to your XWEB 500. If you want to dial your XWEB 500 DIRECT MODEM connection automatically when you start Internet Explorer, do the following. Start Internet Explorer, and select "Internet Options" from the "Tools" menu. Select the "Connections" tab. Make sure that XWEB 500 DIRECT MODEM is your default connection (if not, highlight it and click "Make Default").
  • Page 19: Intranet/Ethernet Connection

    4. INTRANET/ETHERNET CONNECTION The Intranet or Ethernet connection should be initially managed by the net administrator which will assign one free IP address to reach the Server. This number is an example of what you should expect: http://192.168.000.111. After receiving the address from your network Administrator the XWEB 500 must be set with this number.
  • Page 20: Internet Connection

    5. INTERNET CONNECTION It is necessary to have a STATIC IP address for the XWEB 500 which is normally assigned by the Provider of your internet services (ISP). The Internet connection allows XWEB to be reached from all PC-clients. Insert the net address assigned by the administrator into the Browser address bar.
  • Page 21 ALWAYS: ask qualified personnel for the router installation by using this information. Used ports that are mapped to the LAN side: 80 (used for the HTTP access) 22 (used for SSH connection) While the ports on the WAN side are: Telnet (to configure the router from a remote, also via Internet).
  • Page 22: Troubleshooting Guide

    6. TROUBLESHOOTING GUIDE Problem Solution The log-in page doesn’t load Check your browser setup. My password doesn’t allow me Beware to the caps-lock button to log-in. an capitol letters. Is it your password correct? browser can’t reach Check cable typology XWEB 500 log-in page From windows...
  • Page 23: Unit Setup Reminder

    7. UNIT SETUP REMINDER Please take some moments to make an handcopy of this page, then compile it and store it near XWEB unit. HostName ___________________________ IP Address ___________________________ Gateway ___________________________ DNS 1 ___________________________ DNS 2 ___________________________ SMTP ___________________________ E-mail Address ___________________________ Modem ___________________________...

This manual is also suitable for:

Xweb500Dixell xweb500

Table of Contents