GE ZDP30N4HSS Brochure

GE ZDP30N4HSS Brochure

Brochure
Hide thumbs Also See for ZDP30N4HSS:

Quick Links

ZDP30N4HSS
(Natural Gas)
ZDP30L4HSS
(Liquid Propane)
Dimensions and Clearances (in inches)
All Professional Ranges are factory set for natural or liquid propane
gas. The correct model should be ordered for the installation situation.
30" Natural Gas Model
ZDP30N4HSS–4 gas burners
30" Liquid Propane Gas Model
ZDP30L4HSS–4 gas burners
Note: Conversion kits (WB49X10132, Natural to LP and WB49X10133,
LP to Natural) are available if the wrong gas type was ordered. High
Altitude kit, WB49X10130, is also available. The kits must be installed
by a qualified service technician at additional cost.
Installation Information
Before installing, consult installation instructions packed with product
or online at Monogram.com for current dimensional data.
A 30" or 36" wide professional vent hood with a minimum 600 CFM
is recommended for installation over this range. Install the hood
30" to 36" above the cooking surface.
35-1/4"
to
36-3/4"
26-3/4"
Clearances between range and side wall or combustible material
must be at least 12" on each side.
Specification Created 5/04
130540
– GE Monogram 30" Professional Range with 4 Burners
22"
9"
1-1/2"
29-7/8"

Advance Planning

Refer to dimensional drawings for appropriate placement and
necessary clearances when planning the installation.
• Cabinetry cannot be installed directly above the range.
• Working areas adjacent to the range should have 18" minimum
clearance between countertop and cabinet bottom.
• Clearance between range and side wall or combustible material
must be at least 12" on each side.
If the range is installed in an island
• Allow 12" minimum clearance at the back to combustible materials.
• The vent hood blower should provide at least 600 CFM and up to
1200 CFM.
• Installation must conform with local codes. In the absence of local
codes, the range must comply with the National Fuel Gas Code,
ANSI Z223.1-990.
Listed by
Underwriters
Laboratories
R
For answers to your Monogram,
GE
appliance questions, visit our website at
®
GEAppliances.com or call GE Answer Center
service, 800.626.2000.
GE Profile
or
®
®
loading

Summary of Contents for GE ZDP30N4HSS

  • Page 1: Advance Planning

    ZDP30N4HSS (Natural Gas) ZDP30L4HSS – GE Monogram 30" Professional Range with 4 Burners (Liquid Propane) Dimensions and Clearances (in inches) Advance Planning Refer to dimensional drawings for appropriate placement and All Professional Ranges are factory set for natural or liquid propane necessary clearances when planning the installation.
  • Page 2: Electrical Requirements

    ZDP30N4HSS (Natural Gas) ZDP30L4HSS – GE Monogram 30" Professional Range with 4 Burners (Liquid Propane) Electrical Requirements Optional Backsplash Accessories Ranges must be supplied with 208/240V, 60Hz, and connected to The range requires a 12" minimum clearance to a vertical combustible an individual, properly grounded branch circuit protected by a circuit surface at the rear.
  • Page 3 ZDP30N4HSS (Natural Gas) ZDP30L4HSS – GE Monogram 30" Professional Range with 4 Burners (Liquid Propane) Features and Benefits • Sophisticated styling – Designed with chamfered edges and die cast knobs, Monogram stainless steel ranges offer the bold appearance and high-performance cooking capabilities...

This manual is also suitable for:

Zdp30l4hss