10.6.5 Consistency Check Function
The consistency check function performs data matching for all areas of the drives in drive bay 1
and drive bay 2. You can use this function during periodic inspections to increase the
availability of the equipment.
< NOTE >
・ A consistency check can only be done when both drives are in the "ONLINE"
state. For drives in other states, consistency checking is unavailable and you
cannot select the function from the menu window.
・The following table shows guidelines for consistency check time. However, if
there are many data inconsistencies and many sectors to be restored, it might
take longer.
B model (1 TB)
4 hours and 30 minutes
To use the consistency check function, carry out the following procedure:
1. Open the menu window of the software RAID utility. (For details, see 10.6.2 (1).)
B model (2 TB)
10 hours
10-31
T model
40 minutes
10. RAID1