Bosch Therm C 1210 ES Installation And Operating Instructions Manual page 25

Indoor residential and commercial models
Hide thumbs Also See for Therm C 1210 ES:
Table of Contents
Fig. 13
Horizontal venting system (concentric vent)
[1] Exhaust
[2] Combustion air
[3] Exhaust pipe
[4] Drain tee
[5] Intake pipe
[LA] Minimum 1"
Fig. 14
Horizontal parallel venting system (twin pipe direct
vent)
[A] 3 ft minimum
C 1210ES/ESC – 6 720 644 887 (2022/04)
Fig. 15
Horizontal venting system (single pipe penetration)
[1] Exhaust pipe
[2] Drain tee
[3] Intake pipe
[LA] Minimum 4"
WARNING:
▶ Single pipe penetration should be used in non-freezing
climates only and steps must be taken to ensure that
adequate combustion air is available to the water heater at
all times!
4.3.4 Vent connections
Attaching the exhaust and air inlet connection adaptors to
the top of the heater
NOTE: Vent pipe must be completely vertical when inserting or
blue gasket inside exhaust accessory can become displaced.
Exhaust accessory can be removed with vent pipe attached to
check gasket position.
Installation instructions
25