Example Connection
3. FX
/FX
3GC
3UC
FX
-32MT/D
3GC
FX
-32MT/D
3UC
Photo-
coupler
FX
-16EYT
2NC
*2
FX
-16EX
2NC
Photo-
coupler
*1.
Be sure to use the class-D grounding method (grounding resistance: 100 or less).
*2.
Extension blocks are used in the connection example.
Inputs and outputs built into the main unit are available in place of extension blocks.
Apx. - 22
PLC User's Manual - Positioning Control Edition
PLC
Class-D
COM
grounding
X000
*2
COM1
COM1
Y020
Y021
ABS transfer mode
Y022
ABS request
Y023
Y027
COM
X020
X031
X032
Send data ready
X033
X037
Appendix 2-3 Absolute Position Detection (Transistor Output)
CN1
DICOM
24 V DC
DOCOM
*1
Servo-ON
SON 15
ABSM 17
ABSR 18
ABS (bit0)
ABSB0 22
ABS (bit1)
ABSB1 23
ABST 25
ABST 25
SD
Appendix 2. MELSERVO-J3 Series
MR-J3A
Series servo
amplifier
20
46
22
23
Plate