5
|
About the units and options
Installer reference guide
30
Bizone kit (EKMIKPOA or EKMIKPHA)
You can install an optional bizone kit.
For installation instructions, see the installation manual of the bizone kit.
See also:
"6.2.3 Multiple rooms – Two LWT
4
"Bizone
kit" [
 227]
Connection kit for third‑party tank (EKHY3PART)
Required when connecting a third-party tank to the system.
Contains a thermistor, a 3-way valve, and a contactor K3M – terminal X7M
assembly.
For installation instructions, see the installation manual of the connection kit.
Domestic hot water tank
The following domestic hot water tanks are available:
Tank
Stainless steel tank (standard):
EKHWS150D3V3
EKHWS180D3V3
EKHWS200D3V3
EKHWS250D3V3
EKHWS300D3V3
Stainless steel tank (+ components):
EKHWSU150D3V3
EKHWSU180D3V3
EKHWSU200D3V3
EKHWSU250D3V3
EKHWSU300D3V3
Polypropylene tank:
EKHWP300B
EKHWP500B
Polypropylene tank:
EKHWP300PB
EKHWP500PB
For installation instructions, see the installation manual of the domestic hot water
tank, and the addendum book for optional equipment.
Human Comfort Interface (BRC1HHDA) used as room thermostat
The Human Comfort Interface (HCI) used as room thermostat can only be used in
combination with the user interface connected to the indoor unit.
The Human Comfort Interface (HCI) used as room thermostat needs to be
installed in the room that you want to control.
4
zones" [
 43]
Remark
Inclusive booster heater
Inclusive:
Booster heater
Components to comply with the UK
Building Regulation G3.
Tank with drainback solar system.
For these tanks, the booster heater
option (EKBH3SC or EKBH3SD) must be
installed.
Tank with pressurised solar system.
For these tanks, the booster heater
option (EKBH3SC or EKBH3SD) must be
installed.
ERGA04~08EA + EHBH/X04+08EF