Storage Instructions; Storage Conditions - Bosch Rexroth MSK030B-0900-NN Project Planning Manual

Synchronous servomotors
Hide thumbs Also See for Rexroth MSK030B-0900-NN:
Table of Contents
238/279
Bosch Rexroth AG
Transport and storage
10.2

Storage instructions

10.2.1

Storage conditions

Generally, Bosch Rexroth recommends to store all components until they are
actually installed in the machine as follows:
In their original package
At a dry and dustfree location
At room temperature
Free from vibrations
Protected against light or direct insolation
On delivery, protective sleeves and covers may be attached to our motors.
They must remain on the motor for transport and storage. Do not remove
these parts until shortly before assembly.
Based on EN 60721-3-1, the tables below specify classifications and limit
values which are allowed for our products while they are stored. Observe the
detailed description of the classifications to take all of the factors which are
specified in the particular classification into account.
Allowed classes of ambient conditions during storage acc. to EN 60721-3-1
Classification type
Classification of climatic ambient conditions
Classification of biological ambient conditions
Classification of chemically active materials
Classification of mechanically active materials
Classification of mechanical ambient conditions
Tab. 10-3:
Allowed classes of ambient conditions during storage
For the sake of clarity, a few essential environmental factors of the
aforementioned classifications are presented below. Unless otherwise
specified, the values given are the values of the particular class. However,
Bosch Rexroth reserves the right to adjust these values at any time based on
future experiences or changed ambient factors.
Allowed classes of ambient conditions during storage acc. to EN 60721-3-1
Environmental factor
Air temperature
Relative air humidity
Absolute air humidity
Condensation
Ice formation/freezing
Direct solar radiation
Occurence of salt mist
1)
Differs from EN 60721-3-1
Tab. 10-4:
Allowed storage conditions
Before re-storage, empty the liquid coolant from the liquid-cooled
motors to avoid frost damage.
DOK-MOTOR*-MSK********-PR12-EN-P
Synchronous Servomotors MSK
Class
1K2
1B1
1C2
1S1
1M2
Symbol
Unit
Value
T
°C
-20 ... +60
1)
L
φ
%
5 ... 95
ρw
g/m³
1 ... 29
- -
- -
Not allowed
- -
- -
Not allowed
- -
- -
Not allowed
- -
- -
Not allowed
1)
1)

Hide quick links:

Table of Contents
loading

This manual is also suitable for:

Rexroth msk030c-0900-nnRexroth msk040b-0450-nnRexroth msk040b-0600-nnRexroth msk040c-0450-nnRexroth msk040c-0600-nnRexroth msk043c-0600-nn ... Show all

Table of Contents