Installation; Information On Wiring And Circuitry; Electrically Connecting The Sensor - Bosch rexroth PSM Instruction Manual

Spool position sensor
Table of Contents
Pin 2
Pin 1
Y
Connector
DEUTSCH DT04-4P
Fig. 5: Pin assignment
7�3�2 Installation
1� The protective cap is to be removed before installation. The sensor must be
handled with care to prevent damage.
2� Screw the sensor by hand into the intended installation bore and make sure
that the O-ring is not damaged during insertion.
3� Fasten the sensor with the dedicated special tool, the open-ended wrench
SW27 (R913062700). Required tightening torque M
7�3�3 Information on wiring and circuitry
• Lines from the sensor to the electronics must not be routed close to other
power-conducting lines in the machine.
• The wiring harness should be mechanically secured in the area in which
the sensor is installed (distance < 150 mm). The wiring harness should be
secured so that in-phase excitation with the sensor occurs (e.g. at the sensor
mounting point).
• If possible, lines should be routed in the machine interior. If the lines are routed
outside of the machine, their secure mounting is to be ensured.
• Lines must not be kinked or twisted, must not rub against edges and must not be
routed through sharp-edged ducts without protection.
7�3�4 Electrically connecting the sensor
View Y
Pin 3
Pin 4
Table 6: Pin assignment
Pin
Port
1
Supply voltage
2
Ground
3
Output signal 1 (extend tracking pin)
4
Output signal 2 (retract tracking pin)
1� Make sure that the DEUTSCH mating connector is in de-energized condition.
2� Connect the mating connector of the wiring harness to the sensor connector
until it engages noticeably and observe the correct plug-in position.
Installation | PSM
 = 25±2.5 Nm
A
U
bat
GND
RE 95190-B/2021-08-12, Bosch Rexroth AG
17/24