Figure A-5: Accuracy over Measuring Range for Flexible Twin Lead Probe
±0.12 in.
(3 mm)
3.9 in. (10 cm)
12.6 in. (32 cm)
0.4 in. (1 cm)
3.5 in. (9 cm)
F
A. High performance (profile code U)
B. Standard (profile code S)
C. Water (DC = 80)
D. Oil (DC = 2.2)
E. Accuracy
F. Blind Zone
148
A
C
D
±1.18 in.
±0.12 in.
±1.18 in.
(30 mm)
(3 mm)
(30 mm)
E
5.9 in. (15 cm)
9.5 in. (24 cm)
7.9 in.
(20 cm)
C
±0.2 in.
±1.18 in.
(5 mm)
(30 mm)
E
3.9 in. (10 cm)
9.8 in. (25 cm)
0.4 in. (1 cm)
3.5 in. (9 cm)
Reference Manual
00809-0100-4308
B
D
±0.2 in.
±1.18 in.
(5 mm)
(30 mm)
E
E
5.9 in. (15 cm)
9.5 in. (24 cm)
7.9 in.
(20 cm)
Rosemount 3308 Series