Freeze And Block Commands; Unlock - Honeywell 854 ATG Series Instruction Manual

Level gauge
Table of Contents

4.4 Freeze and block commands

Both the freeze (FR) and block (BL) commands stops the displacer at the current position.
With the freeze command, the displacer remains in its position even when the level reaches the displacer
position. Hence, the level can not be followed and the high and high high level alarms can not be generated.
The block command stops the displacer, and depending on how the block mode (item BM) is set, the
displacer will move up with an increasing level, or the block is cancelled when the level reaches the displacer
position.
Item
Name
FR
Freeze
BL
Block
The displacer will remain in its position until an unlock command (UN) is given.
Item BM has to be set (checked) at commissioning (or at a later stage):
Item
Name
W1=
Protection level 1
BM= Block mode
EX
Exit

4.5 Unlock

The unlock command (UN) cancels any of the following operational commands:
• Freeze
(FR)
• Balance test
(BT)
• Go up
(GU)
• Go down
(GD)
• Block
(BL)
• Lock test
(LT)
• Calibrate
(CA)
• Test gauge
(TG)
Item
Name
UN
Unlock
Page 30
Description
The displacer remains in its position even when the level reaches the
displacer position.
The displacer stops at its present position, and depending on the
status of item BM, the displacer will move up with an increasing level,
or the block is cancelled when the level reaches the displacer position.
Description
Enter protection level 1 password
One character; either C (default) or N.
C :
Continuous; when the level reaches the displacer position, the
displacer will follow the increasing level.
N :
Non-continuous; the block mode is cancelled when the level
reaches the displacer position.
Exit protection level
Description
The unlock command cancels the operational commands: BL, BT,
CA, FR, GD, GU, LT and TG.
Operation