Siemens SINUMERIK 840D sl Series Diagnostics Manual page 632

Hide thumbs Also See for SINUMERIK 840D sl Series:
Table of Contents
Overview of Alarms
201256
CU: Opt. module EEPROM incorrect read-write data
Reaction:
NONE
Acknowledge:
NONE
Cause:
Error when reading the read-write data of the EEPROM in the option module.
Fault value (r0949, decimal):
Only for internal Siemens troubleshooting.
Remedy:
- carry-out a POWER ON.
- replace the control unit.
201303
A DriveCliQ component does not support a requested function
Reaction:
OFF2
Acknowledge:
POWER ON
Cause:
A function requested by the control unit is not supported by a DriveCliQ component. Fault
value (r0949, decimal):
Encoder:
1: The encoder module does not support actual value inversion (p410.1==1) when using a
Hall sensor (p404.6==1) for the commutation.
2: The encoder module does not support parking/unparking.
Motor module:
101: The motor module does not support an internal armature short-circuit.
Remedy:
Upgrade the firmware of the DriveCliQ component involved.
201305
Topology: Component number missing
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
The component number from the topology was not parameterized (p0121 (for power
module, refer to p0107), p0131 (for servo/vector drives, refer to p0107), p0141, p0151,
p0161).
Fault value (r0949, decimal):
The fault value includes the particular data set number.
The fault also occurs if speed encoders were configured (p0187 ... p0189), however, no
component numbers exist for them.
In this case, the fault value includes the drive data set number plus 100 * encoder number
(e.g. 3xx, if a component number was not entered into p0141 for the third encoder).
See also: p0121, p0131, p0141, p0142, p0186, p0187, p0188, p0189
Remedy:
Enter the missing component number or remove the component and restart
commissioning.
See also: p0121, p0131, p0141, p0142, p0186, p0187, p0188, p0189
201315
Drive object not ready for operation
Reaction:
NONE
Acknowledge:
NONE
Cause:
For the active drive object involved, at least one activated component is missing.
Note:
All other active and operational drive objects can be in the "RUN" state.
Remedy:
The alarm automatically disappears again with the following actions:
- de-activate the drive object involved (p0105 = 0).
- de-activate the components involved (p0125 = 0, p0145 = 0, p0155 = 0, p0165 = 0).
- re-insert the components involved.
See also: p0105, p0125, p0145
201316
Drive object inactive and again ready for operation
Reaction:
NONE
Acknowledge:
NONE
2-632
SINUMERIK 840D sl/840D/840Di/810D Diagnostics Guide (DA), 08/2005 Edition
© Siemens AG, 2005. All rights reserved
08/2005