LG AMNW07GSJL0 Engineering Product Data Book page 28

Total hvac solution provider multi/single indoor unit r32 heat pump 50 / 60hz 0cti5-02a replaces 0cti5-01c
Hide thumbs Also See for AMNW07GSJL0:
MULTI/SINGLE
2. Specifications
Power Supply
Cooling
Capacity
Heating
Power Input
Min./Nom./Max.
Running Current
Min./Nom./Max.
Casing Color
Body
Dimensions
Shipping
Body
Weight
Shipping
(Row x Column x Fins per inch) x No.
Heat Exchanger
Face Area
Type
Fan
Air Flow Rate
Type
Fan Motor
Output
Sound Pressure Level
Sound Power Level
Liquid
Piping Connections
Gas
Drain
Safety Devices
Connections Method
Power and Communication Cable (included Earth)
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national code. And "Electric characteristics" chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Sound Level Values are measured at Anechoic chamber. Therefore, these values depend on the ambient conditions and values are normally higher
in actual operation.
4. Capacities are net capacities and based on the following conditions. Refer to the Outdoor Unit Specifications for calculating the real capacity.
• Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
17
Indoor unit
Model Name
W x H x D
W x H x D
W x H x D
W x H x D
H / M / L
H / M / L
H / M / L
Max.
O.D. / I.D.
V, Ø, Hz
kW
kW
W x No.
A
-
mm
inch
mm
inch
kg (lbs)
kg (lbs)
-
2
2
m
(ft
)
-
3
m
/min
3
ft
/min
-
W x No.
dB(A)
dB(A)
mm(inch)
mm(inch)
mm
-
-
Thermal Protector for Fan Motor
-
2
No. x mm
(AWG)
Wall Mounted Unit
AMNW24GSKA0
[PM24EP NSK]
220-240, 1, 50
220, 1, 60
6.6
7.5
27 / 45 / 60
0.24 / 0.33 / 0.40
White
998 x 345 x 210
39-9/32 x 13-19/32 x 8-9/32
1,080 x 422 x 281
42-17/32 x 16-5/8 x 11-1/16
12.5 (27.6)
15.8 (34.8)
(2 x 16 x 20) x 1
+ (1 x 8 x 22) x 1
0.28 (3.01)
Cross Flow Fan
15.2 / 12.7 / 10.2
537 / 448 / 360
BLDC
60 x 1
46 / 41 / 36
65
Ø 6.35 (1/4)
Ø 12.7(1/2)
Ø 21.5 / 16.0
Fuse
Flared
4C x 1.0 (18)
loading