X5, Motor Connection - Bosch Rexroth IndraDrive C HCS03.1 Planning Manual

Drive controllers
Table of Contents
Rexroth IndraDrive C HCS03.1

X5, Motor Connection

Connection Cross Section
DOK-INDRV*-HCS03.1****-PR02-EN-P
DANGER
Design
HCS03.1E-
W0070
W0100
W0150
W0210
Fig. 6-26:
Design motor connection
Identification of the individual connections:
Identification
A1
A2
A3
(PE)
Fig. 6-27:
Identification of the individual connections motor connection
HCS03.1E-
W0070
W0100
W0150
W0210
Fig. 6-28:
Connection cross sections motor connection
Dangerous movements caused by unbraked
coasting to stop of the motor in case supply
voltage fails!
⇒ Do not stay within the motional range of the machine.
Possible measures to prevent personnel accidentally
accessing the machine:
- protective fencing
- protective grid
- protective cover
- light barrier.
⇒ Fencing and covers must be adequately secured
against the maximum possible force of movement.
Type
No. of
poles
Connector
4
Terminal block
3
Terminal block
3
Terminal block
3
Significance
phase 1
phase 2
phase 3
equipment grounding conductor
Cross section
[mm²]
16
35
50
95
Electrical Data
Type of design
Screw connection
Screw connection for M6 ring
cable lugs
Screw connection for M6 ring
cable lugs
Screw connection for M10 ring
cable lugs
Cross section
Cross section
flexible
[mm²]
in AWG
-
-
2*25
2*50
4/0
6-19
6
2
0

Hide quick links:

Table of Contents
loading

Table of Contents