Connection Errors To Satellites - GE VersaSafe VersaPoint Series User Manual

Safety logic modul , safe output 24vdc, 8pt
Table of Contents
Table 8-9

Connection errors to satellites

Error cause
Diag-
nostic
code
(hex)
(hex)
Wrong
X3FC
island number
Communication
X5nn
connection
faulty
Incorrect
X7C2
F_Source_
Address
Incorrect
X7C3
operating mode
Incorrect
X7C4
F_Source_
Address
Communication
XDnn
connection
faulty
Table 8-10
Diagnostic codes for faulty communication connection
OAR bit
Diagnostic code bit 0 ... 4
= 0
= 1
4
3
X501
XD01
0
0
X502
XD02
0
0
X503
XD03
0
0
X504
XD04
0
0
X505
XD05
0
0
X506
XD06
0
0
X507
XD07
0
0
X508
XD08
0
1
X509
XD09
0
1
X50A
XD0A
0
1
X50B
XD0B
0
1
X50C
XD0C
0
1
X50D
XD0D
0
1
1
X50E
XD0E
0
X50F
XD0F
0
1
GFK-2731
8.5
Connection errors to satellites
Short description
Island number at IC220SDL953
not set correctly
One or more safe
communication connections are
faulty, see Table 8-10.
IC220SDL953 address settings
in the software and on the device
do not match.
The operating mode set on the
device is not supported.
The F_Source_Address set on
the device is not within the
permissible value range.
See X5nn, the OAR bit is set in the diagnostic register of the IC220SDL953
Faulty connection to
satellite ...
2
1
0
5
4
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
0
0
0
X
0
0
1
X
0
1
0
X
0
1
1
X
1
0
0
X
1
0
1
X
1
1
X
0
1
1
1
X
Chapter 8 Errors: Messages and removal
Remedy
Check switch position
and value in software
and adapt accordingly.
Check and adapt data
status and copy
routines.
Check switch position
and value in software
and adapt accordingly.
Check and correct
switch position.
Check and correct
switch position.
OAR bit
3
2
1
= 0
= 1
X
X511
XD11
X
X512
XD12
X
X
X513
XD13
X
X514
XD14
X
X
X515
XD15
X
X
X516
XD16
X
X
X
X517
XD17
X518
XD18
X
X519
XD19
X
X51A
XD1A
X
X
X51B
XD1B
X
X51C
XD1C
X
X
X51D
XD1D
X
X
X51E
XD1E
X
X
X
X51F
XD1F
Acknowledgment
Reload project.
Acknowledgment required.
(The OAR bit is set in the
diagnostic register of the
IC220SDL953; see "Dev-
Diag-LPSDO (LPSDO
diagnostics)" on page A-18)
Power up.
(The PUR bit is set in the
diagnostic register of the
IC220SDL953; see "Dev-
Diag-LPSDO (LPSDO
diagnostics)" on page A-18)
Diagnostic code bit 0 ... 4
4
3
2
1
0
1
0
0
0
1
1
0
0
1
0
1
0
0
1
1
1
0
1
0
0
1
0
1
0
1
1
0
1
1
0
1
0
1
1
1
1
1
0
0
0
1
1
0
0
1
1
1
0
1
0
1
1
0
1
1
1
1
1
0
0
1
1
1
0
1
1
1
1
1
0
1
1
1
1
1
8
Faulty connection to
satellite ...
5
4
3
2
1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
8-7
Table of Contents
loading

This manual is also suitable for:

Ic220sdl953

Table of Contents