Honeywell HERMetic Operation And Service Manual

Honeywell HERMetic Operation And Service Manual

Sampler a.2 0.5 liter, portable restricted sampling device

Quick Links

Operation and Service Manual
for HERMetic Sampler A.2  0.5 liter
Portable Restricted Sampling Device
Note: before using the instrument
please read this book.
This document is subject to changes without notice.
Check updates on
www.tanksystem.com
or contact us at
1
50403/SA2/1305
HERMetic Sampler A2
Table of Contents
loading

Summary of Contents for Honeywell HERMetic

  • Page 1 Operation and Service Manual for HERMetic Sampler A.2  0.5 liter Portable Restricted Sampling Device Note: before using the instrument please read this book. This document is subject to changes without notice. Check updates on www.tanksystem.com or contact us at [email protected]...
  • Page 2: Table Of Contents

    RUNNING SAMPLING BOTTLE PERATING THE CARE & MAINTENANCE AFETY WARNING AMPLER CLEANING APE CLEANING APE WIPER REPLACEMENT APE REPLACEMENT HERM TORAGE OF ETIC DEVICES HERM RANSPORTATION OF ETIC DEVICES HERM ECYCLING OF ETIC DEVICES SPECIFICATIONS DRAWINGS AMPLER ALVES 50403/SA2/1305 HERMetic Sampler A2...
  • Page 3: Recommendation For Safe Use

    This device is a portable product. It must not be permanently installed on the tank and must be disconnected after use and stored in a safe and dry area. 50403/SA2/1305 HERMetic Sampler A2...
  • Page 4: General Information

    The Purchaser shall bear the caused by the operation of its product and cost risk transportation the warranty is limited to the replacement of defective parts repaired parts parts or complete goods. supplied in replacement of such defective parts. 50403/SA2/1305 HERMetic Sampler A2...
  • Page 5: Certification

    If it is determined that the customers equipment is contaminated, it will be returned to the customer at the customers expense. Contaminated equipment will not be repaired until such time that the customer decontaminates said equipment. 50403/SA2/1305 HERMetic Sampler A2...
  • Page 6 Short description of defective unit or part: ..........................................................................................................................................................................Do you want a quotation before repair is started:..yes / no..... Repaired unit has to be returned to the following address: ................................................................................................................................................................50403/SA2/1305 HERMetic Sampler A2...
  • Page 7: Worldwide Service Stations Network

    Julian Carrillo No. 709 Nte. Fax : +52-833-2170190 COL. LOS MANGOS [email protected] 89440 Cd. MADERO, Tamps, MEXICO NETHERLANDS B.V. TECHNISCH BUREAU Tel : +31-10-4114614 & BELGIUM UITTENBOGAART Fax : +31-10-4141004 Brugwachter 13 [email protected] NL-3034 KD ROTTERDAM 50403/SA2/1305 HERMetic Sampler A2...
  • Page 8 Cherrycourt Way [email protected] LEIGHTON BUZZARD, BEDS, LU7 4TX U.S.A / TEXAS HONEYWELL HERMETIC Tel : +1-281-930 1777 4522 Center Street Fax : +1-281-930 1222 DEER PARK, TX 77536 Toll free call in the USA: 1-800-900 1778 [email protected] 50403/SA2/1305 HERMetic Sampler A2...
  • Page 9: Description

    5. Description 5.1 General The HERMetic Samplers are designed for sampling of liquids or chemicals, which present a Fire-, Health- or Air pollution Hazard. The equipment is designed for use in potentially explosive atmospheres area. 5.2 Sampling types Several kinds of samples can be realised with this sampler. To get different samples, 4 bottles are available: Zone bottle, Spot bottle, Running bottle and Bottom bottle.
  • Page 10: Sampling Principle

    5.3.1 Connection and grounding system All HERMetic products are easy to connect. Indeed, all HERMetic devices are equipped with a quick coupler for connection on a HERMetic ball valve. Place the unit on the appropriate valve and activate the locking system. Depending on the locking system, either rotate the collar and actuate the lever or pull on the sleeve.
  • Page 11: Sampling Method

    5.3.3 Liquid transfer To transfer the fluid, no additional equipment is necessary. Just remove the sampling bottle through bottom of Sampler and pour its content into an appropriated laboratory bottle. 50403/SA2/1305 HERMetic Sampler A2...
  • Page 12: Operation

    Nota: Clean the instrument of any excess of liquid after use. Remove the winder holder and clean the storage tube. This cleaning must be done very properly, in particular when corrosive liquids are gauged, such as strong acids or caustic soda for instance. Store the instrument in a dry location. 50403/SA2/1305 HERMetic Sampler A2...
  • Page 13: O Perating The Zone Sampling Bottle

    2” neck diameter. Reassemble the bottle and cover to the sampler. Remove the sampler from the valve. Reinstall the 2” cover on top of the valve. Clean the equipment after use and check it for proper functioning. 50403/SA2/1305 HERMetic Sampler A2...
  • Page 14: O Perating The Bottom Sampling Bottle

    Reassemble the bottom bottle and the cover to the sampler. Remove the sampler from the valve. Reinstall the 2” cover on top of the valve. Clean the equipment after use and check it for proper functioning. 50403/SA2/1305 HERMetic Sampler A2...
  • Page 15: O Perating The Spot Sampling Bottle

    Reassemble the spot bottle and the cover to the sampler. Remove the sampler from the valve. Reinstall the 2” cover on top of the valve. Clean the equipment after use and check it for proper functioning. 50403/SA2/1305 HERMetic Sampler A2...
  • Page 16: O Perating The Running Sampling Bottle

    Reassemble the running bottle and the cover to the sampler. Remove the sampler from the valve. Reinstall the 2” cover on top of the valve. Clean the equipment after use and check it for proper functioning. 50403/SA2/1305 HERMetic Sampler A2...
  • Page 17: Care & Maintenance

    Resistance should not exceed 100 . 7.3 Sampler cleaning To clean HERMetic Sampler A2, winder holder can be easily removed and sampling bottle detached from tape. It is required to fit the cleanliness level with the sample goals. Where appropriate, dismantle the winder holder and clean the parts with an appropriate cleaner to prevent any contamination of the sample by the sampler itself.
  • Page 18: Tape Cleaning

     Put back the tape wiper.  Put back the winder holder and tighten the 2 screws. Storage of HERMetic devices For a proper storage of HERMetic products (UTImeter, Sampler, Thermometer and related spare- parts…), we recommend: Clean the devices after use, •...
  • Page 19: Specifications

    Meets ISO 3170 “Petroleum liquids – Manual sampling” Tape cleaning device Adjustable tape cleaner Available bottles Zone, bottom, spot, running sampling bottles Maintenance modular design / easy exchange of parts Specifications subject to change without notice. 50403/SA2/1305 HERMetic Sampler A2...
  • Page 20: Drawings

    These documents are enclosed in following pages. 9.1 Sampler O = Option, according to specific order. DESCRIPTION 20319 10042 Hermetic Sampler A2-0,5 l. 30 m 30386 10302 Winder tape 30 m metric/inch 40796 10369 Tape assy w/o winder 30 m...