Tap Pin Assignment And Function - Allen-Bradley Guardmaster GuardLink User Manual

Safety system
Table of Contents
Tap Pin Assignment and
Function
Each tap has three M12 quick disconnect connectors
is designed to use premanufactured patchcords to facilitate installation,
modification, and troubleshooting. The link connectors are 4-pin. The device
connectors are either 5-pin or 8-pin.
Figure 20 - Tap Connection Identification
J1
GuardLink Link In
4-Pin M12 Male
The link connections carry the power and command signals.
the functions of each pin. When using Allen-Bradley® Guardmaster patchcords
and safety devices, you do not need to be concerned about the pin assignments,
the system is connect and go.
Figure 21 - Link Connections
2: GuardLink Safety
1: +24V DC
3: 0V DC
4: GuardLink CLU
J1 Link In (Male)
Pin
Function
1
+24V Supply (+10%, -15%)
2
GuardLink Safety Signal
3
0V DC, the reference for the 24V supply
4
GuardLink Control Lock Unlock (CLU) Signal
Figure 22...Figure 25
show the functions that are assigned to the 8-pin and
5-pin quick-disconnect connections for safety devices.
Figure 22 - J3 8-Pin OSSD (Female) Connector
2: +24V DC
1: Aux
7: 0V
6: Safety OSSD B
Pin
Function
1
The auxiliary status output signal is not used by the tap
2
+24V Supply (+10%, -15%)
3
The Lock/Unlock command to the device
4
Safety OSSD channel B+ (24V DC)
5
Safety OSSD channel A
6
Safety OSSD channel B
7
0V DC, the reference for the 24V supply
8
Safety OSSD channel A+ (24V DC)
Rockwell Automation Publication 440R-UM015C-EN-P - April 2018
J3
8-Pin M12 Female or
INPUT
5-Pin M12 Female
J2
4-Pin M12 Female
2: GuardLink Safety
1: +24V DC
4: GuardLink CLU
J2 Link Out (Female)
3: Lock/Unlock Command
8: Safety OSSD A+
4: Safety OSSD B+
5: Safety OSSD A
Power, Ground, and Wire
Chapter 4
(Figure
20). The system
GuardLink Device Connection
GuardLink Link Out
Figure 21
shows
3: 0V DC
39
Table of Contents
loading