Allen-Bradley Micro800 Installation Instructions Manual

Allen-Bradley Micro800 Installation Instructions Manual

4-channel and 8-channel analog voltage/current input and output modules
Hide thumbs Also See for Micro800:
Installation Instructions
Micro800 4-channel and 8-channel Analog
Voltage/Current Input and Output Modules
Catalog Numbers
http://www.rockwellautomation.com/literature/
Cette publication est disponible en français
sous forme électronique (fichier PDF). Pour la
FR
télécharger, rendez-vous sur la page Internet
indiquée ci-dessus.
Questa pubblicazione è disponibile in Italiano
in formato PDF. Per scaricarla collegarsi al sito
IT
Web indicato sopra.
Diese Publikation ist als PDF auf Deutsch
verfügbar. Gehen Sie auf die oben genannte
DE
Web-Adresse, um nach der Publikation zu
suchen und sie herunterzuladen.
Esta publicación está disponible en español
como PDF. Diríjase a la dirección web indicada
ES
arriba para buscar y descarga esta publicación.

Table of Contents

Topic
2085-IF4, 2085-IF8, 2085-OF4
Esta publicação está disponível em portugués
como PDF. Vá ao endereço web que aparece
PT
acima para encontrar e fazer download da
publicação.
ZH
ZC
KR
Page
2
5
5
6
6
9
9
loading

Summary of Contents for Allen-Bradley Micro800

  • Page 1: Table Of Contents

    Installation Instructions Micro800 4-channel and 8-channel Analog Voltage/Current Input and Output Modules 2085-IF4, 2085-IF8, 2085-OF4 Catalog Numbers http://www.rockwellautomation.com/literature/ Cette publication est disponible en français Esta publicação está disponível em portugués sous forme électronique (fichier PDF). Pour la como PDF. Vá ao endereço web que aparece télécharger, rendez-vous sur la page Internet...
  • Page 2: Important User Information

    Micro800 4-channel and 8-channel Analog Voltage/Current Input and Output Modules Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.rockwellautomation.com/literature/) describes some important differences...
  • Page 3 Micro800 4-channel and 8-channel Analog Voltage/Current Input and Output Modules Environment and Enclosure ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating.
  • Page 4 Micro800 4-channel and 8-channel Analog Voltage/Current Input and Output Modules North American Hazardous Location Approval The following modules are North American Hazardous Location approved: 2085-IF4, 2085-IF8, 2085-OF4 The following information applies when operating Informations sur l’utilisation de cet équipement en...
  • Page 5: Additional Resources

    • purchase a printed manual by contacting your local Allen-Bradley distributor or Rockwell Automation representative Overview The Micro800™ expansion I/O is a modular I/O that complements and extends the capabilities of Micro850™ controllers. These expansion I/O modules interface with Micro850 controllers using an I/O expansion port.
  • Page 6: Module Description

    Micro800 4-channel and 8-channel Analog Voltage/Current Input and Output Modules 2085-IF8 45318 45319 Front view Right top view Module Description Description Description Mounting screw hole / mounting foot Module interconnect latch Removable Terminal Block (RTB) DIN rail mounting latch RTB hold down screws I/O status LED This equipment is sensitive to electrostatic discharge (ESD).
  • Page 7 Micro800 4-channel and 8-channel Analog Voltage/Current Input and Output Modules Module Spacing Maintain spacing from objects such as enclosure walls, wireways and adjacent equipment. Allow 50.8 mm (2 in.) of space on all sides for adequate ventilation, as shown. Mounting Dimensions and DIN Rail Mounting 44.5 mm (1.75 in.)
  • Page 8 System Assembly The Micro800 expansion I/O module is attached to the controller or another I/O module by means of interconnecting latches and hooks, as well as the bus connector. The Micro850 controller and expansion I/O modules must terminate with a 2085-ECR Bus Terminator module.
  • Page 9: Wire The Modules

    Micro800 4-channel and 8-channel Analog Voltage/Current Input and Output Modules ATTENTION: To comply with UL restrictions, this equipment must be powered from a source compliant with the following: Class 2 or Limited Voltage/Current. Wire the Modules Included with your 2085-IF4 or 2085-OF4 module is a single 12-pin Removable Terminal Blocks (RTB).
  • Page 10 Micro800 4-channel and 8-channel Analog Voltage/Current Input and Output Modules General Specifications Attribute 2085-IF4 2085-OF4 2085-IF8 Wiring category 2 – on signal ports Wire type Shielded Terminal screw torque 0.5…0.6 Nm (4.4…5.3 lb-in.) Power dissipation, total 1.7 W 3.7 W 1.75 W...
  • Page 11 Micro800 4-channel and 8-channel Analog Voltage/Current Input and Output Modules Output Specifications – 2085-OF4 Attribute 2085-OF4 Number of outputs Resolution 12 bits unipolar; 11 bits plus sign bipolar Voltage 2.56 mV/cnt unipolar; 5.13 mV/cnt bipolar Current 5.13 A/cnt Data format...
  • Page 12 Declaration of Conformity, Certificates, and other certification details. Allen-Bradley, Rockwell Automation, Micro800 and TechConnect are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page...