  • Page 1: Table Of Contents

    Installation Instructions Original Instructions Micro800 Programmable Controller External AC Power Supply Catalog Numbers 2080-PSAC-12W Topic Page Important User Information Overview Connect the Power Supply Wire the Module Specifications...
  • Page 2: Important User Information

    Micro800 Programmable Controller External AC Power Supply Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards.
  • Page 3 Micro800 Programmable Controller External AC Power Supply WARNING: Identifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss. ATTENTION: Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss.
  • Page 4 Micro800 Programmable Controller External AC Power Supply Environment and Enclosure ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in IEC 60664-1), at altitudes up to 2000 m (6562 ft) without derating.
  • Page 5 Micro800 Programmable Controller External AC Power Supply North American Hazardous Location Approval The following information applies when Informations sur l’utilisation de cet équipement en operating this equipment in hazardous locations. environnements dangereux. Les produits marqués "CL I, DIV 2, GP A, B, C, D" ne Products marked "CL I, DIV 2, GP A, B, C, D"...
  • Page 6 Micro800 Programmable Controller External AC Power Supply ATTENTION: • Be careful when stripping wires. Wire fragments that fall into the controller could cause damage. Once wiring is complete, be sure the module is free of all metal fragments before removing the protective debris strip. Failure to remove the strip before operating can cause overheating.
  • Page 7: Overview

    Micro800 Programmable Controller External AC Power Supply Overview The 2080-PSAC-12W power supply can be used by controllers from the Micro800® family as an optional AC power source. Rockwell Automation Publication 2080-IN011B-EN-P - August 2016...
  • Page 8: Connect The Power Supply

    Micro800 Programmable Controller External AC Power Supply Connect the Power Supply Measurements in millimeters 110.7 General Considerations Most applications require installation in an industrial enclosure to reduce the effects of electrical interference and environmental exposure. Locate your module as far as possible from power lines, load lines, and other sources of electrical noise such as hard-contact switches, relays, and AC motor drives.
  • Page 9: Wire The Module

    Micro800 Programmable Controller External AC Power Supply DIN Rail Mounting Use a flat-blade screwdriver to mount the power supply on EN50022-35x7.5 DIN rails. Panel Mounting The preferred mounting method is to use four M4 (#8) screws per module. Hole spacing tolerance: ±0.4 mm (0.016 in.).
  • Page 10: Specifications

    Micro800 Programmable Controller External AC Power Supply AC Input Connectors DC Output Connectors (DC 24V / 0.5 A) PAC-1 AC hot 100...240V AC DC-1 PAC-2 AC neutral 100...240V AC DC-2 PAC-3 Safety ground ATTENTION: Replace the finger guard after wiring the power supply.
  • Page 11 Micro800 Programmable Controller External AC Power Supply General Attribute Value 24V, 0.9 A, 21.6W @ 50 °C Output ratings 24V, 0.5 A, 12W @ 65 °C Enclosure type rating Meets IP20 0.32... 2.1 mm² (22...14 AWG) solid copper wire or Wire size 0.32...
  • Page 12 Micro800 Programmable Controller External AC Power Supply Environmental Attribute Value IEC 60068-2-27 (Test Ea, Unpackaged Shock): Shock, nonoperating 25 g for DIN rail mounted 45 g for panel mounted Emissions IEC 61000-6-4 IEC 61000-4-2: ESD immunity 6 kV contact discharges...
  • Page 13 Micro800 Programmable Controller External AC Power Supply Certifications Certification (when Value product is marked) UL Listed Industrial Control Equipment, certified for US and Canada. See UL File E322657. c-UL-us UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations, certified for U.S. and Canada.
  • Page 14 Micro800 Programmable Controller External AC Power Supply 中国 RoHS 指令符合性表 China RoHS Compliance Table 有毒或有害的物质和元素 Toxic or Hazardous Substances and Elements 部件名称 六价铬 多溴联苯 多溴二苯醚 鉛 汞 鎘 Component Name Hexavalent Polybrominated Polybrominated Lead Mercury Cadmium Chromium Biphenyls Diphenyl Ethers...
  • Page 15 Micro800 Programmable Controller External AC Power Supply Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Description A more detailed description of how to install and use Micro810 Programmable Controllers your Micro810® LC10 programmable controller and...
  • Page 16 At the end of its life, this equipment should be collected separately from any unsorted municipal waste. Allen-Bradley, Rockwell Automation, Rockwell Software, Micro800, Micro810, Micro820, Micro830, and Micro850 are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.