GE AF-600 FP Operating Instructions Manual page 82

Fan and pump drive 460v/575v 150hp and above
Hide thumbs Also See for AF-600 FP:
Table of Contents
How to Program
6.1.4 Main Menu Mode
The keypad provides access to the main menu mode.
Select the Main Menu mode by pressing the [Main Menu]
key. Illustration 6.2 shows the resulting read-out, which
appears on the display of the keypad.
Lines 2 through 5 on the display show a list of parameter
groups which can be chosen by toggling the up and down
buttons.
Illustration 6.8 Display example.
Each parameter has character(s) and number which remain
the same regardless of the programming mode. In the
Main Menu mode, the parameters are further divided into
groups: Macros, Keypad Set-Up, Parameter Data Set,
Parameter Data Check, Drive Information, Data Readouts,
Logs & I/O Option Status, and Advanced Parameter Data
Set.
All parameters can be changed in the Main Menu. The
configuration of the unit (H-40 Configuration Mode) will
determine other parameters available for programming.
For example, selecting Closed Loop enables additional
parameters related to closed loop operation. Option cards
added to the unit enable additional parameters associated
with the option device.
6.1.5 Parameter Selection
Main Menu Item
Parameter Groups:
Keypad Set-Up
K-##
Parameter Data
F-##, E-##, C-##, P-##, H-##, AN-##, SP-##, O-
Set
##, AO-##, DN-##, PB-##, LN-##, BN-##
Drive Information ID-##
Data Readouts
DR-##
Logs & I/O Option
LG-##
Status
Advanced
AP-##, FB-##, T-##, CL-##, XC-##, PC-##, LC-##,
Parameter Data
B-##
Set
Table 6.3 Parameter Groups in Main Menu Items
AF-600 FP High Power Operating Instructions
Group no.
K-##
F-##
E-##
C-##
P-##
H-##
AN-##
SP-##
O-##
AO-##
DN-##
PB-##
LN-##
BN-##
ID-##
DR-##
LG-##
AP-##
FB-##
EN-##
T-##
CL-##
XC-##
PC-##
LC-##
B-##
Table 6.4 Parameter groups.
Choose a parameter group from the Main Menu and Press
[OK]. Then further select the parameter sub-groups by
using the up and down arrows and then Press [OK].
The middle section of the keypad display shows the
parameters. Press [OK] to select parameters and now the
display shows that selected parameter's value.
6.1.6 Changing Data
1.
2.
3.
4.
5.
6.
7.
Parameter group:
Keypad Set-Up
Fundamental Parameters
Digital In/Out
Frequency Control Functions
Motor Data
High Perf Parameters
Analog In/Out
Special Functions
Options / Comms
Analog I/O Option
DeviceNet
Profibus
LonWorks
BACnet
Drive Information
Data Readouts
Logs & I/O Opt. Status
HVAC Appl. Param.
Fire/Bypass Operation
EtherNet
Timed Functions
PID Closed Loop
Ext. PID Closed Loop
Pump Controller
Logic Controller
Braking Functions
Press [Quick Menu] or [Main Menu] key.
Use [
] and [
] keys keys to find parameter
group to edit.
Press [OK] key.
Use [
] and [
] keys to find parameter to edit.
Press [OK] key.
Use [
] and [
] keys to select correct parameter
setting. Or, to move to digits within a number,
use left or right arrow keys. Cursor indicates digit
selected to change. [
] key increases the value,
[
] key decreases the value.
Press [Cancel] key to disregard change, or press
[OK] key to accept change and enter new setting.
6
6
81
Table of Contents
loading

Table of Contents