  • Page 1 GE Consumer & Industrial Electrical Distribution AF-600 FP & AF-650 GP OPCGPIO General Purpose I/O Option Module...
  • Page 2 The OPCGPIO option includes 3 digital inputs, 2 analog inputs, 2 digital outputs and 1 analog output. SW firmware version to be installed in the drive control card must be version 3.00 or later versions for AF-650 GP series, and version X.XX for AF-600 FP series.
  • Page 3 AF-650 GP and AF-600 FP OPCGPIO General Purpose I/O Option Module 1.2.1 Galvanic Isolation in the OPCGPIO Digital/analog inputs are galvanically isolated from other inputs/outputs on the OPCGPIO and in the control card of the frequency converter. Digital/analogue outputs in the OPCGPIO are galvanically isolated from other inputs/outputs on the OPCGPIO, but not from these on the control card of the drive. If the digital inputs 7, 8 or 9 are to be switched by use of the internal 24 V power supply (terminal 9) the connection between terminal 1 and 5 which is illustrated in the drawing has to be established.
  • Page 4 AF-650 GP and AF-600 FP OPCGPIO General Purpose I/O Option Module 1.2.2 Digital inputs - Terminal X30/1-4 Parameters for set-up: E-53, E-54 and E-55 Number of digital Voltage level Voltage levels Tolerance Max. Input impedance inputs 0-24 V DC PNP type: ±...
  • Page 5: Mounting Of Option Modules In Slot B

    AF-650 GP and AF-600 FP OPCGPIO General Purpose I/O Option Module 1.3.1 Mounting of Option Modules in Slot B The power to the frequency converter must be disconnected. For Unit Sizes 12, 13 and 23: • Remove the Keypad, the terminal cover, and the Keypad frame from the frequency converter. •...
  • Page 6 AF-650 GP and AF-600 FP OPCGPIO General Purpose I/O Option Module 1.3.2 Mounting Guidelines - Step By Step These step-by-step instructions describe how to mount the control cables: • The power to the frequency converter must be disconnected. • Remove the Keypad, the terminal cover, and the Keypad frame from the frequency converter. •...
  • Page 7 Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to the GE company. AF-600 FP and AF-650 GP are trademarks of the General Electric Company.