Installer Settings: Tables To Be Filled In By Installer; Quick Wizard; Space Heating Control; Domestic Hot Water Control [A.4] - Daikin EGSQH10S18AA9W User Reference Manual

Altherma ground source heat pump
Hide thumbs Also See for EGSQH10S18AA9W:
Table of Contents
INFORMATION
▪ Indoor unit relates to indoor unit PCB which controls the
hydraulic part of the ground source heat pump.
▪ Outdoor unit relates to outdoor unit PCB which controls
the  compressor  module  of  the  ground  source  heat
pump.
4.9
Installer settings: Tables to be
filled in by installer
4.9.1
Quick wizard
Setting
Backup heater configuration (only for unified backup heater)
[A.2.1.5]
BUH type
Preferential kWh rate power supply [A.2.1.6]
Preferential kWh rate
Space heating settings [A.2.1]
Unit control method
User interface location
Number of LWT zones
Pump operation mode
Domestic hot water settings [A.2.2]
DHW pump
Thermostats [A.2.2]
Contact type main
Contact type add.
External sensor
Digital I/O PCB [A.2.2.6]
Ext. backup heat src
Alarm output
Demand PCB [A.2.2.7]
Demand PCB
Energy metering [A.2.2]
External kWh meter 1
External kWh meter 2
Capacities (energy metering) [A.2.3]
BUH: step 1
BUH: step 2
Auto emergency [A.5.1.2]
Auto emergency operation
INFORMATION
Auto  emergency:  By  default,  backup  heater  operation
during  emergency  operation  is  NOT  allowed.  This  means
that  when  a  heat  pump  failure  occurs  the  user  needs  to
manually  confirm  that  backup  heater  may  operate  during
emergency.  If  the  house  is  unattended  for  longer  periods,
we  recommend  that  setting  [A.5.1.2]  Auto  emergency
operation shall be set to Automatic.
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351749­1 – 2013.06
Default
Fill in...
4 (3PN,(1/2))
0 (No)
0 (LWT
control)
1 (In room)
0 (1 LWT
zone)
1 (Sample)
0 (No)
1 (Thermo
ON/OFF)
1 (Thermo
ON/OFF)
0 (No)
0 (No)
0 (Normally
open)
0 (No)
0 (No)
0 (No)
3 kW
3 kW
Manual
4.9.2
Space heating control
Setting
Leaving water temperature: Main zone [A.3.1.1]
LWT setpoint mode
Set weather­dependent heating
Leaving water temperature: Additional zone [A.3.1.2]
LWT setpoint mode
Set weather­dependent heating
Leaving water temperature: Delta T emitter [A.3.1.3]
Heating
Leaving water temperature: Modulation [A.3.1.1.5]
Modulated LWT
Leaving water temperature: Emitter type [A.3.1.1.7]
Emitter type
4.9.3
Domestic hot water control [A.4]
Setting
Type
Setpoint readout type
Maximum setpoint
4.9.4
Contact/helpdesk number [6.3.2]
Setting
Contact/helpdesk number
5
Energy saving tips
Tips about room temperature
▪ Make sure the desired room temperature is NEVER too high, but
ALWAYS according to your actual needs. Each saved degree can
save up to 6% of heating costs.
▪ Do  NOT  increase  the  desired  room  temperature  to  speed  up
space heating. The space will NOT heat up faster.
▪ When  your  system  layout  contains  slow  heat  emitters  (example:
under  floor  heating),  avoid  large  fluctuation  of  the  desired  room
temperature and do NOT let the room temperature drop too low. It
will take more time and energy to heat up the room again.
▪ Use  a  weekly  schedule  for  your  normal  space  heating  needs.  If
necessary, you can easily deviate from the schedule:
▪ For  shorter  periods:  You  can  overrule  the  scheduled  room
temperature.  Example:  When  you  have  a  party,  or  when  you
are leaving for a couple of hours.
▪ For  longer  periods:  You  can  use  the  holiday  mode.  Example:
When  you  stay  at  home  during  your  holiday,  or  when  you  go
away during your holiday.
Tips about leaving water temperature
▪ In  heating  mode,  a  lower  desired  leaving  water  temperature
results in lower energy consumption and better performance.
▪ Set the desired leaving water temperature in accordance with the
heat  emitter  type.  Example:  Underfloor  heating  is  designed  for
lower  leaving  water  temperature  than  radiators  and  heat  pump
convectors.
5 Energy saving tips
Default
Fill in...
1 (Weather
dep.)
–20/15/60/25
1 (Weather
dep.)
25/60/15/−20
8°C
0 (No)
0 (Quick)
Default
Fill in...
1 (Reheat +
sched.)
0
(Temperature)
60°C
Default
Fill in...
User reference guide
19
Table of Contents
loading

Table of Contents