Check if he has filled in the installer settings tables. If not, request him to do so. ▪ Keep the documentation for future reference. Target audience End users Documentation set This document is part of a documentation set. The complete set Main zone. Example: Living room. consists of: Additional zone. Example: Bedroom. Technical room. Example: Garage. Brine loop Indoor unit heat pump Domestic hot water (DHW) tank User interface at the indoor unit User interface in the living room, used as room thermostat Underfloor heating Operation manual EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P3517501 – 2013.06...
▪ Goes to the default home page (when you are in the menu The DHW tank booster mode is active or ready to be structure). activated. MALFUNCTION INFORMATION Quiet mode is active. If a malfunction occurs, is displayed on the home pages. Press to display more information about the malfunction. Holiday mode is active or ready to be activated. ON/OFF Child lock mode and/or function lock mode is active. Turns ON or OFF one of the controls (room temperature, leaving water temperature, DHW tank temperature). EGSQH10S18AA9W Operation manual Daikin Altherma ground source heat pump 4P3517501 – 2013.06...
or to adjust the temperature. 50°C 40°C To change the mode from scheduled to preset value Prerequisite: User profile = Detailed. 15°C 1 Go to the room temperature home page (Room). 2 Press or to select a preset value ( or ). 00:00 07:00 14:00 21:00 Result: The mode will return to Scheduled according to the overrule period. ▪ T : DHW tank temperature To set the overrule period ▪ t: Time 1 Go to [7.2]: > User settings > Temperature lock. 2 Select a value and press ▪ Permanent ▪ hours (2, 4, 6, 8) Operation manual EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P3517501 – 2013.06...
To read out and overrule the active or next scheduled desired To select which schedule you currently want to use temperature (in scheduled mode or scheduled + reheat mode) 1 Go to [5]: > Select schedules. 1 Go to the DHW tank temperature home page (Tank). 2 Select for which control you want to use a schedule. Example: [5.1] Room temperature. Result: or is displayed. 3 Select for which operation mode you want to use a schedule. 2 Press or to overrule. Note: If the desired temperature is Example: [5.1.1] Heating. weather dependent, you cannot change it on the home page. 4 Select a predefined or userdefined schedule and press EGSQH10S18AA9W Operation manual Daikin Altherma ground source heat pump 4P3517501 – 2013.06...
Quiet mode DHW pump [7.4] Preset values Room temperature LWT main Tank temperature Quiet level INFORMATION Energy metering functionality is NOT applicable and/or NOT valid for this unit if it is calculated by the unit. If optional external meters are used, energy metering display is valid. Operation manual EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P3517501 – 2013.06...
▪ Make sure the desired DHW tank temperature is NOT too high. Example: After installation, lower the DHW tank temperature daily Leaving water temperature: Additional zone [A.3.1.2] by 1°C and check if you still have enough hot water. LWT setpoint mode 0 (Fixed) ▪ Program to turn ON the domestic hot water pump only during Set weatherdependent heating 25/40/15/−10 periods of the day when instant hot water is necessary. Example: Leaving water temperature: Delta T emitter [A.3.1.3] In the morning and evening. Heating 5°C Leaving water temperature: Modulation [A.3.1.1.5] Modulated LWT 0 (No) Leaving water temperature: Emitter type [A.3.1.1.7] Emitter type 1 (Slow) EGSQH10S18AA9W Operation manual Daikin Altherma ground source heat pump 4P3517501 – 2013.06...
Hot water used, in any type of building, for domestic purposes. Symptom: You are feeling too cold LWT = Leaving water temperature (hot) in your living room Water temperature at the water outlet of the heat pump. Possible cause Corrective action The desired room temperature is Increase (decrease) the desired too low (high). room temperature. If the problem recurs daily, do one of the following: ▪ Increase (decrease) the room temperature preset value. ▪ Adjust the room temperature schedule. The desired room temperature Increase the desired leaving cannot be reached. water temperature in accordance with the heat emitter type. Operation manual EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P3517501 – 2013.06...