Daikin Altherma ground source heat pump
User reference guide
English
Daikin Altherma ground source heat pump
EGSQH10S18AA9W
Table of Contents
loading

Summary of Contents for Daikin EGSQH10S18AA9W

  • Page 1 User reference guide Daikin Altherma ground source heat pump User reference guide English Daikin Altherma ground source heat pump EGSQH10S18AA9W...
  • Page 2: Table Of Contents

    6 Maintenance and service person responsible for their safety. Children must be supervised to Overview: Maintenance and service.......... 20 ensure that they do not play with the product. To find the contact/helpdesk number ........20 CAUTION 7 Troubleshooting Do NOT rinse the unit. This may cause electric shocks or Overview: Troubleshooting............20 fire. To check the error history............20 Symptom: You are feeling too cold (hot) in your living room ..20 Symptom: The water at the tap is too cold ........ 20 Symptom: Heat pump failure ............. 21 User reference guide EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 3: About This Document 3

    Underfloor heating precautions operating your system Heat pump convectors or fan coil units Operation Quick guide for basic manual usage INFORMATION User Detailed step­by­step Digital files on http:// The  indoor  unit  and  the  domestic  hot  water  tank  (if reference instructions and www.daikineurope.com/ installed) can be separated or integrated depending on the guide background information support­and­manuals/ indoor unit type. for basic and advanced product­information/. usage Latest revisions of the supplied documentation may be available on the regional Daikin website or via your installer. EGSQH10S18AA9W User reference guide Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 4: Operation

    (if  applicable) on the home pages. ▪ Goes  to  the  next  step  (when  you  are  programming  a schedule in the menu structure). ▪ Enables you to activate or deactivate child lock if pressed for more than 5 seconds on a home page. ▪ Enables  you  to  activate  or  deactivate  a  function  lock  if pressed for more than 5 seconds in the main menu of the menu structure. INFORMATION If you press   or   while changing settings, the changes will NOT be applied. User reference guide EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 5: Status Icons

    Turning ON/OFF controls Weather­dependent mode is active. About turning ON/OFF controls User permission level = Installer. Before you can control… You have to turn ON… Defrost/oil return mode is active. Room temperature Room temperature control Hot start mode is active. (Room) Emergency operation is active. Main (+ additional) leaving water Main (+ additional) leaving water temperature temperature control (LWT main and LWT add) INFORMATION Main and additional leaving Quiet mode is NOT applicable for this unit. water temperature control are always turned ON or OFF together. DHW tank temperature Domestic hot water control (Tank) If you turn ON… Then… Room temperature control Main (+ additional) leaving water temperature control is automatically turned ON. Main (+ additional) leaving water Room temperature control is temperature control NOT automatically turned ON. EGSQH10S18AA9W User reference guide Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 6: Space Heating Control

    ▪ Leaving  water 45°C Desired temperature temperature  (main + additional) Mon 17:30 Desired temperature Set the space operation mode. Menu structure 2 Go to [6]:   > Information. Restrict when automatic changeover is possible. 3 Press   for more than 5 seconds. Result:  The  user  permission  level  switches  to  Adv.  end  user. Additional information is displayed and "+" is added to the menu title. 4 Check the following: User reference guide EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 7 If you do this, you also have to define (in the leaving water temperature schedule (main). menu structure): See also: ▪ Preset values ▪ "Using  the  leaving  water  temperature  home  pages  (main  + ▪ Overrule period (Temperature lock) additional)" on page 9 Select which room temperature schedule Menu structure ▪ "4.7 Preset values and schedules" on page 15 you want to use. Program schedules. Define preset values that are used by the room temperature schedule, and when you change the mode from scheduled to preset value. See also: ▪ "Using the room temperature home page" on page 8 ▪ "To set the overrule period" on page 9 ▪ "4.7 Preset values and schedules" on page 15 EGSQH10S18AA9W User reference guide Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 8 4 Operation Example: Temporarily overruling the schedule AND changing External room thermostat control the mode to preset value External  room  thermostat  control  means  that  you  control  the You have configured the following settings: following: ▪ Room temperature on the external thermostat control Settings Description Preset values Comfort (heating) = Desired temperature when ▪ Leaving water temperature on the user interface (Daikin) 20°C you are at home. Eco (heating) = 18°C Desired temperature: To control the leaving water temperature, you can do the following: ▪ When you are away You can… Location ▪ During the night Read out the desired leaving water Leaving water Schedule 07:00 Comfort You are at home.
  • Page 9 ▪ Tonight  you  have  a  party  and  you  want  to  use  the  preset  value (Comfort) until 02:00. To read out the desired leaving water temperature (main + additional) Go to the leaving water temperature home page (LWT main or LWT Then you can do the following: add). 1 Set the overrule period (Temperature lock) to 6 hours. 2 At 20:00, go to the room temperature home page (Room). 3 Press   to select  . Result:  The  preset  value  (Comfort)  will  be  used  until  02:00. After that, the schedule will be used again. EGSQH10S18AA9W User reference guide Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 10: Domestic Hot Water Control

    This  start­up  can  be  set  by  installer  settings the day when instant hot water is necessary. (disinfection function). See also: ▪ When the Domestic hot water > Type > Scheduled only ▪ "4.5.5 Using the DHW tank temperature home page" on page 11 is  selected,  it  is  recommended  to  program  a  Storage eco  3  hours  before  the  scheduled  start­up  of  the ▪ "4.5.6 Using the DHW tank booster mode" on page 12 disinfection function to preheat the tank. ▪ "4.7 Preset values and schedules" on page 15 To determine which DHW tank mode you are using (method 1) Check the installer settings table filled in by the installer. User reference guide EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 11: Scheduled Mode

    15:20 Condition:   is displayed on the DHW tank 60°C Tank Tank temperature home page. 60°C Storage comfort Activate the DHW tank booster mode. Select a DHW tank temperature schedule. Menu structure 00:00 Desired temperature Program a DHW tank temperature schedule. Define preset values that are used by the 15:20 15:20 DHW tank temperature schedule. Tank Tank (Only for field supplied domestic hot water Storage comfort pump for secondary return) Program a domestic hot water pump schedule 00:00 Desired temperature to determine when to turn ON and OFF the pump. When turned ON, the pump runs and makes sure hot water is instantly available at the tap. To save energy, only turn ON the pump during periods of the day when instant hot water is necessary. EGSQH10S18AA9W User reference guide Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 12: Using The Dhw Tank Booster Mode

    2 Overrule  the  next  scheduled  action  by  doing  one  of  the following: ▪ Change  from  55°C  to  60°C  (when  defining  hot  water  as temperature) ▪ Change  from  2  persons  to  3  persons  (when  defining  hot water as number of persons) User reference guide EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 13: Advanced Usage

    From  2 February 2013 activated,  but  NOT  running Until  16 February 2013 yet. Operation mode  Heating  ▪ Holiday  mode  (Home)  is Heating  12°C activated.  You  cannot  see  if the  holiday  mode  is  already 2 Activate the holiday mode. running. ▪ Go to [2.1]:   > Holiday > Holiday. ▪ Select Yes and press  EGSQH10S18AA9W User reference guide Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 14: Reading Out Information

    20.0°C [6.4] User permission level  Current user permission level. Actual temperature If  user  permission  level  =  Adv.  end  user,  you  can  read  out  the following additional information: Detailed  15:20 20.0°C Room In menu… You can read out… [6.1] Sensor information  Room, tank or DHW, outside, Actual temperature and leaving water temperature. (If applicable) Scheduled 17:30 [6.2] Energy metering  Produced energy, consumed electricity, and consumed gas. User reference guide EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 15: Locking And Unlocking Buttons And Functions

    2 Select  for  which  control  you  want  to  define  a  preset  value. supplied turned ON and OFF. Example: Room temperature. domestic hot water pump for 3 Select  a  preset  value  and  press  .  Example:  Comfort secondary return) (heating). Domestic hot water 4 Select a temperature and press  pump Start heating up until the desired setpoint (Comfort/Eco) is reached. Stop heating, even if the desired temperature is not reached yet; example: if electric tariffs are higher during the day, you can program a stop at 06:00. EGSQH10S18AA9W User reference guide Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 16: Schedules: Example

      >  User  settings  >  Set  schedules  >  Room temp. > Set heating schedule. 2 Select Empty and press  3 Program the schedule for Monday. See below for more details. 4 Copy  from  Monday  to  Tuesday,  Wednesday,  Thursday  and Friday. See below for more details. 5 Program the schedule for Saturday. 6 Copy from Saturday to Sunday. 7 Save  the  schedule  and  give  it  a  name.  See  below  for  more details. User reference guide EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 17: Predefined Schedules: Leaving Water Temperature (Additional)

    Predefined 3 Mon ­ Sun 08:00 23:00 4.7.6 Predefined schedules: DHW tank temperature :  Start  production  of  domestic  hot  water.  Desired  DHW  tank temperature = Preset value (Storage comfort) :  Start  production  of  domestic  hot  water.  Desired  DHW  tank temperature = Preset value (Storage eco) Predefined 1 Mon ­ Sun Predefined 2 Mon ­ Sun Predefined 3 Mon ­ Fri Sat ­ Sun EGSQH10S18AA9W User reference guide Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 18: Menu Structure: Overview

    DHW pump [7.4] Preset values Room temperature LWT main Tank temperature Quiet level INFORMATION INFORMATION Energy  metering  functionality  is  NOT  applicable  and/or Quiet mode and quiet level is NOT applicable for this unit. NOT  valid  for  this  unit  if  it  is  calculated  by  the  unit.  If optional external meters are used, energy metering display is valid. User reference guide EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 19: Installer Settings: Tables To Be Filled In By Installer

    [A.5.1.2]  Auto  emergency ▪ In  heating  mode,  a  lower  desired  leaving  water  temperature operation shall be set to Automatic. results in lower energy consumption and better performance. ▪ Set the desired leaving water temperature in accordance with the heat  emitter  type.  Example:  Underfloor  heating  is  designed  for lower  leaving  water  temperature  than  radiators  and  heat  pump convectors. EGSQH10S18AA9W User reference guide Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 20: Maintenance And Service

    Go to [6.3.2]:   > Information > Error handling > Contact/helpdesk number. If the problems recurs daily, do one of the following: ▪ Increase  the  DHW  tank temperature preset value. ▪ Adjust  the  DHW  tank temperature  schedule. Example:  Program  additionally  heat  up  DHW  tank  to  a  preset  value (Storage  eco  =  lower  tank temperature) during the day. User reference guide EGSQH10S18AA9W Daikin Altherma ground source heat pump 4P351749­1 – 2013.06...
  • Page 21: Symptom: Heat Pump Failure

    If  you  want  to  dispose  parts  of  your  system  (user  interface,  indoor combined  with  the  product  according  to  the  instructions  in unit, outdoor unit, DHW tank…), contact your installer. You can find the accompanying documentation. the contact/helpdesk number via the user interface. Field supply Equipment  not  made  by  Daikin  that  can  be  combined  with the  product  according  to  the  instructions  in  the accompanying documentation. EGSQH10S18AA9W User reference guide Daikin Altherma ground source heat pump...
  • Page 24 4P351749­1  2013.06...