Output Sequence Editor; Require Output Sequence - Honeywell Hyperion 1300g User Manual

General purpose handheld linear scanner
Hide thumbs Also See for Hyperion 1300g:
Table of Contents
The breakdown of the command line is shown below:
SEQBLK sequence editor start command
62
code identifier for Code 39
0012
A - Code 39 sample length (11) plus CR suffix (1) = 12
41
start character match for Code 39, 41h = "A"
FF
termination string for first code
6A
code identifier for Code 128
0013
B - Code 128 sample length (12) plus CR suffix (1) = 13
42
start character match for Code 128, 42h = "B"
FF
termination string for second code
69
code identifier for Code 93
0012
C - Code 93 sample length (11) plus CR suffix (1) = 12
43
start character match for Code 93, 43h = "C"
FF
termination string for third code

Output Sequence Editor

Enter Sequence

Require Output Sequence

When an output sequence is Required , all output data must conform to an
edited sequence or the image scanner will not transmit the output data to the
host device. When it's On/Not Required , the image scanner will attempt to get
the output data to conform to an edited sequence, but if it cannot, the image
scanner transmits all output data to the host device as is.
Default Sequence
3 - 13