Honeywell Xenon CCB01-010BT-BF Quick Start Manual

Honeywell Xenon CCB01-010BT-BF Quick Start Manual

Cordless area-imaging scanner for healthcare and charge bases
Hide thumbs Also See for Xenon CCB01-010BT-BF:
Xenon™ XP 1952h/1952h-BF
CCB01-010BT/CCB01-010BT-BF
CCB-H-010BT/CCB-H-010BT-BF
Cordless Area-Imaging Scanner for Healthcare and Charge Bases
Quick Start Guide
1952HC-HCBF-EN-QS-01 Rev A
04/19
Table of Contents
loading

Summary of Contents for Honeywell Xenon CCB01-010BT-BF

  • Page 1 Xenon™ XP 1952h/1952h-BF CCB01-010BT/CCB01-010BT-BF CCB-H-010BT/CCB-H-010BT-BF Cordless Area-Imaging Scanner for Healthcare and Charge Bases Quick Start Guide 1952HC-HCBF-EN-QS-01 Rev A 04/19...
  • Page 2: Get Started

    Agency Model: 1952, 1952-BF, CCB01-010BT, CCB01-010BT-BF, CCB-H-010BT, CCB-H-010BT-BF Note: Refer to your User Guide for information about cleaning your device. Get Started Turn off computer’s power before connecting the scanner, then power up the computer once the scanner is fully connected. Once the base is connected and powered up, follow the Link the Scanner...
  • Page 3: Connect The Scanner

    Connect the Scanner USB: Note: If you are charging the scanner using the USB cable, the current available for charging is reduced and charge times are increased. Charging via the power supply is faster. CCB01-010BT or CCB01-010BT-BF Base: CCB-H-010BT or CCB-H-010BT-BF Base:...
  • Page 4: Keyboard Wedge

    Keyboard Wedge: CCB01-010BT or CCB01-010BT-BF Base: CCB-H-010BT or CCB-H-010BT-BF Base:...
  • Page 5: Rs232 Serial Port

    RS232 Serial Port: CCB01-010BT or CCB01-010BT-BF Base: CCB-H-010BT or CCB-H-010BT-BF Base:...
  • Page 6 Link the Scanner Use the following procedure to configure all scanners so they automatically connect to the base. Scan the bar code on the base. Place the scanner into the base. Power cycle the base to complete the link and establish communication between the base and scanner.
  • Page 7: Reading Techniques

    USB Serial If you are using a Microsoft® Windows® PC, you must download a driver from the Honeywell website. The driver will use the next available COM Port number. Scan the following code to program the scanner to emulate a regular RS232-based COM Port.
  • Page 8: Usb Pc Keyboard

    USB PC Keyboard Scan the following code to program the scanner for a USB PC Keyboard. USB PC Keyboard Epic Scan the following bar code to configure your device to commu- nicate with an Epic software application. EMR Application After scanning this code, you must put the scanner into the base or scan the linking bar code on the base or Access Point to relink your scanner.
  • Page 9 Meditech® Scan the following bar code to configure your device to commu- nicate with a Meditech software application. Meditech Application After scanning this code, you must put the scanner into the base or scan the linking bar code on the base or Access Point to relink your scanner.
  • Page 10 Silent Mode with Flashing LED Scan the following bar code to completely silence the base and scanner. When a bar code is scanned, the LED and aimer flash 5 times. Green indicates a good scan, red indicates a bad scan. Silent Mode with Flashing LED Silent Mode with Long LED Scan the following bar code to completely silence the base and...
  • Page 11 Very Low Beeper (Nighttime Mode) The following bar code silences the base, and sets the scanner for a very low beep when reading bar codes. After scanning this code, the base beep, base and scanner power up beep, and scanner linking sounds are all silenced. When a bar code is scanned, the scanner emits a very soft beep.
  • Page 12: Page Button

    Page Button The page button on the base is used to page your scanner or to put it into Temporary Streaming Presentation mode. When the scanner is out of the base, press the page button once to make the scanner beep so you can locate it. Press the scanner’s trig- ger to stop the page beeping.
  • Page 13: Add Code Id Prefix To All Symbologies

    Suffix If you want a carriage return after the bar code, scan the Add CR Suffix bar code. To add a tab after the bar code, scan the Add Tab Suffix bar code. Otherwise, scan the Remove Suffix bar code to remove the suffixes. Add CR Suffix Add Tab Suffix Remove Suffix...
  • Page 14: Keyboard Country

    Keyboard Country Scan the appropriate country code below to program the key- board layout for your country or language. By default, national character replacements are used for the following characters: #$@[\]^‘{|}~ Refer to the ISO 646 Character Replacements chart in your User Guide to view the character replacements for each country.
  • Page 15 Great Britain Italy Norway Spain Switzerland Note: For a complete list of country codes, see the User Guide for your product. EZConfig-Scanning To access additional features for the scanner, use EZConfig- Scanning, an online configuration software tool, available from website. Support To search our knowledge base for a solution or to log into the Technical Support portal and report a problem, go to...
  • Page 16: Product Documentation

    Patents For patent information, see www.hsmpats.com. Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made.
  • Page 17 Copyright  2019 Honeywell International Inc. All rights reserved.