7-14 Troubleshooting
component does not reach the threshold and the reinstallation cannot be performed
as it is determined that repair is needed. Typically, device replacement is required.
Contact your maintenance service engineer. If the integration needs to be done with
the current devices, you can forcibly reinstall the currenlty used device through
consultation with the maintenance service engineer.
kernel: EVLOG: ERROR - x is now STATE_BROKEN /
REASON_BELOW_MTBF
(x is a device number)
Nothing appears on the screen
 At the startup, the screen is connected to the CPU/IO module of the
primary side through the HW switch. When it is disconnected from the
CPU/IO module because the module cause a failure, the screen black out
without switching to another CPU/IO module.
About syslog
A log indicating the insmod command (driver load) failed is recorded in syslog
 The following log may be recorded, but the contents of such log do not
affect the system.
insmod: a module named adp94xx already exists <27>
insmod: insmod
/lib/modules/2.4.21-47.0.1.ELvmnix/updates/lsb-ft/extra/adp94xx.o
failed
insmod:
/lib/modules/2.4.21-47.0.1.ELvmnix/kernel/drivers/char/i810_rng.o:
insmod i810_rng failed
insmod:
/lib/modules/2.4.21-47.0.1.ELvmnix/kernel/drivers/usb/host/uhci.o:
insmod
/lib/modules/2.4.21-47.0.1.ELvmnix/kernel/drivers/usb/host/uhci.o failed
insmod:
/lib/modules/2.4.21-47.0.1.ELvmnix/kernel/drivers/usb/host/ehci-hcd.o:
insmod ehci-hcd failed