7-6 Troubleshooting
On-screen error message
0B95 BMC FRU device failure
0B96 BMC SDR Repository
failure
0B97 BMC SEL device failure
0B98 BMC RAM test error
0B99 BMC Fatal hardware
error
0B9A BMC not responding
0B9B Private I2C bus not
responding
0B9C BMC internal exception
0B9D BMC A/D timeout error
0B9E SDR repository corrupt
0B9F SEL corrupt
0BA0 SDR/PIA mismatched.
SDR, PIA must be
updated.
0BB0 SMBIOS - SROM data
read error
0BB1 SMBIOS - SROM data
checksum bad
0BC0 POST detected startup
failure of 1st Processor
0BC1 POST detected startup
failure of 2nd Processor
8100 Memory Error detected
in DIMM group #1
8101 Memory Error detected
in DIMM group #2
8102 Memory Error detected
in DIMM group #3
8120 Unsupported DIMM
detected in DIMM group
#1
8121 Unsupported DIMM
detected in DIMM group
#2
8122 Unsupported DIMM
detected in DIMM group
#3
Cause
NVRAM within BMC is faulty.
SDR repository within BMC
is faulty.
SEL repository within BMC is
faulty.
BMC RAM is faulty.
BMC FPGA is faulty.
BMC device is faulty.
I2C bus is faulty.
BMC device is faulty.
SDR data is faulty.
SEL repository within BMC is
faulty.
SDR and PIA data do not
match.
I2C bus is faulty.
SROM is faulty.
BMC is faulty.
Data within SROM is faulty.
CPU is faulty.
DIMM is faulty..
Unsupported DIMM is
mounted.
Action
Replace the CPU/IO module.
If updating FPGA does not help,
replace the CPU/IO module or ft
Remote Management Card
(option).
Replace the CPU/IO module.
If turning AC power off and on
does not help, replace the
CPU/IO module or the system
backboard.
Replace the CPU/IO module.
If updating SDR does not help,
replace the CPU/IO module or ft
Remote Management Card
(option).
Replace the CPU/IO module.
If updating SDR/PIA does not
help, replace CPU/IO module.
If turning AC power off and on
does not help, replace the system
backboard.
Replace the CPU.
Replace the DIMM Slot0 (2
DIMMs).
Replace the DIMM Slot1 (2
DIMMs).
Replace the DIMM Slot2 (2
DIMMs).
Check supported DIMMs and
replace them. If replacing the
DIMMs does not help, replace the
CPU/IO module.