Setting Stay Mode 2 Zones; Satellite Siren Service Mode; Turning Telephone Monitor Mode On And Off - Bosch ICP-CC488 Installation Manual

Hide thumbs Also See for ICP-CC488:
Table of Contents
ICP-CC488 | Installation Guide | 5.0
To program the telco disarm sequence:
1. Enter the Installer Code and press [3][AWAY].
Three beeps sound and the STAY and AWAY
indicators flash.
2. Press [2][AWAY] to change the telco disarming
sequence.
Three beeps sound.
If a telco disarming sequence is already
programmed, the sequence is displayed one digit
at a time using the remote codepad indicators.
Refer to Table 21 on page 24 for the indicators
and their meanings.
If no telco disarming sequence is programmed,
an additional two beeps sound after entering this
mode. These two beeps normally sound after the
last digit of the sequence is displayed.
3. Enter the desired call forward disable sequence.
For example, program [# 6 1 #] to disable the
call forward – no answer sequence, or [# 2 1 #]
to disable the call forward – immediate sequence.
Remember that when you program a # in
the telco arm sequence, you enter
[STAY][2].
4. Press [AWAY].
Two beeps sound and the system returns to the
disarmed state.
You can suspend the telco disarming sequence at any
time.
To disable the telco disarming sequence:
Enter the Installer Code and press [3][AWAY][2]
[AWAY][STAY][4][AWAY].
5.1.5

Setting STAY Mode 2 Zones

This function allows the installer to select the zones
that are automatically isolated when the system is
armed in STAY Mode 2.
To arm the system in STAY Mode 2, press and hold
[0] until two beeps sound. Refer to Section 5.4.3 or
Section 3.5 Arming The System in STAY Mode 2 for more
information.
To set STAY Mode 2 zones:
1. Enter the Installer Code and press [4][AWAY].
Three beeps sound and the STAY indicator
flashes.
2. Enter the number of the zone you want to
automatically isolate and press [STAY].
The corresponding zone indicator flashes.
3. Repeat Step 2 for each zone you want to select.
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
System Functions
As each zone is selected to be isolated,
the corresponding zone indicator flashes.
If you make a mistake, enter the incorrect
zone number and press [STAY]. This zone
is no longer selected to be isolated and
the zone indicator is extinguished.
This function does not work on a
partitioned ICP-CC488 Control Panel.
4. Press [AWAY].
Two beeps sound and the system returns to the
disarmed state.
The indicators for the zones you selected and the
STAY indicator are extinguished.
Example
If you want to select zones 2, 5, and 6, enter:
[1 2 3 4 4][AWAY][2][STAY][5][STAY][6][STAY]
[AWAY]
You can disable all zones selected to be automatically
isolated for STAY Mode 2 at any time. To disable
STAY Mode 2 zones:
Enter the Installer Code and press [4][AWAY]
[AWAY].
5.1.6

Satellite Siren Service Mode

If the SS914 Satellite Siren (EDMSAT) is connected
to Output 1, this function allows you to perform
service work on the system without activating the
satellite siren. The satellite siren returns to its normal
working state the next time the system is armed.
To enter Satellite Siren Service Mode:
Enter the Installer Code and press [5][AWAY].
Three beeps sound.
5.1.7
Turning Telephone Monitor Mode On
and Off
Telephone Monitor Mode allows you to use the
remote codepad for visual representation of data
transmissions between the control panel and the base
station receiver. The dialing sequence is also shown
in this mode.
The codepad beeps once every two sec when
Telephone Monitor Mode is active, whether the
system is in Installer's Programming Mode or normal
operating mode. The first five indicators show the
progressive steps during a transmission to the base
station receiver.
After you activate Telephone Monitor Mode, hold
down [9] until two beeps sound to initiate a Test
Report.
EN | 25
Table of Contents
loading

Table of Contents