Summary of Contents for Bosch AMAX panel 2000 ICP-AMAX-P

  • Page 1 AMAX panel 2000 / AMAX panel 2000 EN ICP-AMAX-P / ICP-AMAX-P-EN User Guide...
  • Page 3: Table Of Contents

    Bypassing Faults and Tamper conditions (Except Zone Tampers) Codes Enable / Disable the installer codes Change individual code Keypad alarm operation commands Duress alarm Keypad panic alarm Keypad fire alarm Keypad medical alarm Domestic Dialing Bosch Sicherheitssysteme GmbH User Guide F.01U.249.500 | V4 | 2011.12...
  • Page 4: Introduction

    Fire alarm Simultaneously press and hold [4] and [6] Medical alarm Simultaneously press and hold [7] and [9] Default user code = 2580 Table 1.1 Quick keypad operation instructions F.01U.249.500 | V4 | 2011.12 User Guide Bosch Sicherheitssysteme GmbH...
  • Page 5 FAULTS System fault or Tamper condition is present. System is in normal status. Flashes System fault or Tamper condition must be acknowledged. System is disarmed. Table 1.2 Keypad Indicators Bosch Sicherheitssysteme GmbH User Guide F.01U.249.500 | V4 | 2011.12...
  • Page 6 Keypad fault/tamper sound (fault/tamper to be acknowledged) – Keypad alarm sound Continuous 0.5 Entry delay time (until alarm ends or system is disarmed). second beep, stops 0.5 seconds Table 1.3 Keypad sounds F.01U.249.500 | V4 | 2011.12 User Guide Bosch Sicherheitssysteme GmbH...
  • Page 7 Code 11 _____________________________________________________ Keyfob 3 Code 12 _____________________________________________________ Keyfob 4 Code 13 _____________________________________________________ Keyfob 5 Code 14 _____________________________________________________ Keyfob 6 Code 15 _____________________________________________________ Keyfob 7 Code 16 _____________________________________________________ Keyfob 8 Bosch Sicherheitssysteme GmbH User Guide F.01U.249.500 | V4 | 2011.12...
  • Page 8: Arming And Disarming The System

    Users can use a key switch to Arm and Disarm the system. When the Key switch is activated, the AWAY indicator flashes slow and exit time starts. After exit time, the AWAY indicator is lit. F.01U.249.500 | V4 | 2011.12 User Guide Bosch Sicherheitssysteme GmbH...
  • Page 9: Arming In Stay Mode

    Press and hold the Disarming Button. Two beeps sound and the AWAY or STAY indicator is extinguished. 2.2.3 Disarming with Key switch When the Key switch is deactivated, the system is disarmed and the AWAY or STAY indicator is extinguished. Bosch Sicherheitssysteme GmbH User Guide F.01U.249.500 | V4 | 2011.12...
  • Page 10: Faults Or Tamper Conditions

    To exit from Fault and Tamper Analysis Mode, press [#] . The STAY and AWAY indicators are extinguished and the FAULT indicator remains lit, and the keypad stops the beep. F.01U.249.500 | V4 | 2011.12 User Guide Bosch Sicherheitssysteme GmbH...
  • Page 11 DX 3010 Fail B420/DX 4020 /-G Fail Power Faults AC Fault Fault Battery Aux Power Supply Fault Bosch Option Bus Power Fault RF Power Fault Warning Device Failure List Warning Device 1 Disconnected Warning Device 1 Short Warning Device 2 Disconnected...
  • Page 12: Walk Test Mode

    Unseal and seal the zones to be tested. The keypad sounds one second beep and the siren sounds one beep each time when a Zone status is changed. F.01U.249.500 | V4 | 2011.12 User Guide Bosch Sicherheitssysteme GmbH...
  • Page 13: Event Memory Recall Mode

    If the system is armed in STAY mode, the STAY indicator shows the event memory playback. If the control panel is powered down the memory of all events is saved. Bosch Sicherheitssysteme GmbH User Guide F.01U.249.500 | V4 | 2011.12...
  • Page 14: Reset The Control Panel

    Enter your code and then press [6] [#]. The keypad beeps twice and the signal is eliminated. NOTICE! You can reset alarms, faults or tamper conditions, only when they are not active anymore. F.01U.249.500 | V4 | 2011.12 User Guide Bosch Sicherheitssysteme GmbH...
  • Page 15: Bypassing

    After bypassing a Fault or Tamper condition, you can arm the system even when a Fault or Tamper condition exists. How to bypass faults and tamper conditions Enter user code + [97] and press [#]. Two beeps sound. Bosch Sicherheitssysteme GmbH User Guide F.01U.249.500 | V4 | 2011.12...
  • Page 16: Codes

    This function is automatically terminated if you do not press a button within 240 seconds or if you press [#]. One long beep indicates that the code already exists or that you entered an incorrect user number. F.01U.249.500 | V4 | 2011.12 User Guide Bosch Sicherheitssysteme GmbH...
  • Page 17: Keypad Alarm Operation Commands

    Keypad medical alarm If you simultaneously press and hold [7] and [9], a silent keypad emergency medical alarm will be transmitted. Please contact your installer to enable/disable the emergency medical alarm functionality Bosch Sicherheitssysteme GmbH User Guide F.01U.249.500 | V4 | 2011.12...
  • Page 18: Domestic Dialing

    The user presses [#] between two acknowledgement tones to confirm the alarm. If the control panel got the [#] acknowledgement from the user, it will send 2 second long beep as acknowledge tone and hang up the line. F.01U.249.500 | V4 | 2011.12 User Guide Bosch Sicherheitssysteme GmbH...
  • Page 20 Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.com © Bosch Sicherheitssysteme GmbH, 2011...