Standard Functions - Hitachi WJ200 Series Instruction Manual

Wj200 series single-phase input 200v class three-phase input 200v class three-phase input 400v class
Hide thumbs Also See for WJ200 Series:
Table of Contents

Standard Functions

NOTE:. Mark " " in B031=10 shows the accessible parameters when B031 is set "10",
high level access.
Func.
Name
Code
Frequency source
A001
Frequency source,
A201
2
motor
nd
Run command source
A002
Run command source,
A202
2
motor
nd
Base frequency
A003
Base frequency,
A203
2
motor
nd
Maximum frequency
A004
Maximum frequency,
A204
2
motor
nd
[AT] selection
A005
[O] input active range start
A011
frequency
[O] input active range end
A012
frequency
[O] input active range start
A013
voltage
"A" Function
Description
Eight options; select codes:
00 ...POT on ext. operator
01 ...Control terminal
02 ...Function F001 setting
03 ...ModBus network input
04 ...Option
06 ...Pulse train input
07 ...via EzSQ
10 ...Calculate function output
Five options; select codes:
01 ...Control terminal
02 ...Run key on keypad,
or digital operator
03 ...ModBus network input
04 ...Option
Settable from 30 Hz to the
maximum frequency(A004)
Settable from 30 Hz to the 2
maximum frequency(A204)
Settable from the base
frequency to 400 Hz
Settable from the 2
frequency to 400 Hz
Three options; select codes:
00...Select between [O] and [OI]
at [AT] (ON=OI, OFF=O)
02...Select between [O] and
external POT at [AT]
(ON=POT, OFF=O)
03...Select between [OI] and
external POT at [AT]
(ON=POT, OFF=OI)
The output frequency
corresponding to the analog
input range starting point,
range is 0.00 to 400.0
The output frequency
corresponding to the analog
input range ending point,
range is 0.0 to 400.0
The starting point (offset) for
the active analog input range,
range is 0. to 100.
Run
Mode
Lnitial data
Edit
nd
base
nd
C−3
Defaults
Units
02
02
02
02
60.0
Hz
60.0
Hz
60.0
Hz
60.0
Hz
00
0.00
Hz
0.00
Hz
0.
%