Mitsubishi Electric FR-E720-008 Instruction Manual page 310

Hide thumbs Also See for FR-E720-008:
Table of Contents
Inspection items
Reinstallation
1) After confirming the orientation of the fan, reinstall
the fan so that the arrow on the left of "AIR FLOW"
faces up.
2) Reconnect the fan connectors.
3) When wiring, avoid the cables being caught by the fan.
FR-E720-175(SC) or less
FR-E740-095(SC) or less
FR-E720S-050 to 110
4) Reinstall the fan cover.
FR-E720-175(SC) or less
FR-E740-095(SC) or less
FR-E720S-050 to 110
2. Insert hooks until you
hear a click sound.
Example for FR-E740-095
NOTE
Installing the fan in the opposite of air flow direction can cause the inverter life to be shorter.
Prevent the cable from being caught when installing a fan.
Switch the power OFF before replacing fans. Since the inverter circuits are charged with voltage even after
power OFF, replace fans only when the inverter cover is on the inverter to prevent an electric shock
accident.
310
FR-E720-240(SC) or more
FR-E740-120(SC) or more
FR-E720-240(SC) or more
FR-E740-120(SC) or more
1. Insert hooks
into holes.
1. Insert hooks
into holes.
Example for FR-E740-120
AIR FLOW
2. Insert hooks until
you hear a click
sound.