5.4.5. Sling configuration for top lifting rails
2
60°
max
Key:
(1)
Shackle
(2)
Sling slope angle (maximum 60°)
(3)
Top lifting rail
Fig. 38. Sling configuration - standard case with top lifting rails
5.5. Storage
5.5.1. Storage conditions
The minimum requirements for storage are based on IEC 60721-3-1.
Conditions: 1K22 / 1B1 / 1C2 / 1S11 / 1M11
–
5.5.1.1. Storage time
The drive can be stored for up to one year in the original packaging as long as it is not damaged
or opened.
NOTE – For information on longer storage periods, contact the ABB service organization.
5.5.2. Storing the drive
If the drive is taken out of service for a longer time proceed as follows:
1. Remove the batteries (if applicable).
2. Cover all cable inlets and ventilation slots with an impermeable plastic or aluminum foil and
a wooden panel.