2-3-19. MAX GAIN Adjustment

Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in low illuminance will not be produced
(dark).
Subject:
Clear chart (Center frame)
Adjustment page:
6F
Adjustment address:
2C
m
. Perform "Flange Back Adjustment" (Sections 2-3-4 and 2-3-5) before this adjustment.
. If reading/writing data on page 6F, set data:06 to page:0, address:10, and then select page F. By this data
setting, the page 6F can be selected.
After the data reading/writing fi nished, return the data on page:0, address:10 to "00".
. Check that the data of page:6, address:02 is "00". If not, select page:6, address:01, set data:00, and press
the PAUSE button.
Adjusting procedure
Order
Page
Address
1
2
0
01
3
6
4D
4
6
2C
5
6
40
6
6
41
7
6
C9
8
6
D0
9
6
D1
10
6
01
11
6
02
12
0
10
13
F
2C
(6F)
14
6F
2C
15
0
10
*1: The adjustment data will be automatically input to page:6F, address:2C.
2-40
Data
Operation
Check that the picture frame is "Center Frame". If not, perform
"2-3-18. Picture Frame Setting (Center Frame)".
01
40
01
01
01
10
Set the following data.
. NTSC model: 2C
. PAL model:
00
6F
Press the PAUSE button. (*1)
Check that the data changes to "01".
06
If the data is as follows, the adjustment is completed.
. NTSC model: 4B-5A
. PAL model:
If the data is as follows, go to step 13.
. NTSC model: 5B-61
. PAL model:
Set the following data.
. NTSC model: 5A
. PAL model:
00
Check that the data changes to "01".
1C
6E-7A
7B-8A
7A