GE PACSystems RSTi User Manual
GE PACSystems RSTi User Manual

GE PACSystems RSTi User Manual

Profibus and profinet network adapter
Hide thumbs Also See for PACSystems RSTi:
Table of Contents

Quick Links

GE
Intelligent Platforms
Programmable Control Products
PACSystems* RSTi
PROFIBUS and PROFINET Network
Adapter
User's Manual, GFK-2746B
August 2013
Table of Contents
loading

Summary of Contents for GE PACSystems RSTi

  • Page 1 Intelligent Platforms Programmable Control Products PACSystems* RSTi PROFIBUS and PROFINET Network Adapter User’s Manual, GFK-2746B August 2013...
  • Page 2 No warranties of merchantability or fitness for purpose shall apply. * indicates a trademark of GE Intelligent Platforms, Inc. and/or its affiliates. All other trademarks are the property of their respective owners. ©Copyright 2013 GE Intelligent Platforms, Inc.
  • Page 3 Contact Information If you purchased this product through an Authorized Channel Partner, please contact the seller directly. General Contact Information Online technical support and GlobalCare http://www.ge-ip.com/support Additional information http://www.ge-ip.com/ Solution Provider [email protected] Technical Support If you have technical problems that cannot be resolved with the information in this guide, please contact us by telephone or email, or on the web at www.ge-ip.com/support...
  • Page 5: Table Of Contents

    Contents Introduction ..................... 9 I/O Station Capacity ..................10 Network Topology ..................10 Installation ..................... 10 IOGuidePro Tool for Configuration & Monitoring .......... 10 Features ......................11 List of RSTi Network adapters ..............11 PACSystems Documentation................ 11 Installation ..................... 12 Module Mounting ..................
  • Page 6 Contents 3.2.5 PROFIBUS Communication Interface ............41 3.2.6 Choice of PROFIBUS data transfer cable type..........42 3.2.7 PROFIBUS Module Configuration ..............44 3.2.7.1 System and Field Power cable wiring............44 3.2.7.2 Station Address and Quick Startup Mode Setup ........45 3.2.7.3 Adding GSD file ..................
  • Page 7 Contents Product Certifications and Installation Guidelines for Conformance ..85 Important Notes .................... 85 Safety Notes....................85 Certifications ....................85 Government Regulations ................86 Environmental Specifications ................ 87 GFK-2746B PACSystems* RSTi PROFIBUS and PROFINET Network Adapter–August 2013...
  • Page 9: Introduction

    Chapter 1. Introduction Introduction The PACSystems RSTi Network Interface and I/O family provides a cost effective, modular distributed I/O system. The RSTi network is ideally suited for distributed applications such as water/wastewater, process control, packaging and assembly. You can easily add RSTi modules to the system to build functional remote I/O stations to meet your application requirements.
  • Page 10: I/O Station Capacity

    IOGuidePro Tool for Configuration & Monitoring PACSystems RSTi Network adapters can be configured & monitored using IOGuidePro tool. You can use the IOGuidePro Tool to monitor & configure the following data: ...
  • Page 11: Features

    16 Positive Logic in/8 relay out isolated  STXPBS925 16 Negative Logic in/8 relay out isolated RSTi PROFINET Network Adapter  STXPNS001 PROFINET network adapter PACSystems Documentation ■ PACSystems RSTi I/O Manual – GFK 2745 GFK-2746B PACSystems* RSTi PROFIBUS and PROFINET Network Adapter–August 2013...
  • Page 12: Installation

    Chapter 2. Installation Installation Warning Installing or removing modules or wiring with power applied to the system or field wiring can cause an electrical arc. This can result in unexpected and potentially dangerous action by field devices. Arcing is an explosion risk in hazardous locations. Be sure that the area is non- hazardous or remove power appropriately before installing or removing modules or wiring.
  • Page 13: Module Mounting

    Chapter 2. Installation Module Mounting 2.1.1 How to Mount on DIN Rail 1. Press down the module lightly on the DIN Rail until it clicks & locks. Figure 1: Pressing down the module lightly 2. . You can use the PUSH lock for DIN rail up as a second locking mechanism. Figure 2: PUSH lock as a second locking mechanism GFK-2746B PACSystems* RSTi PROFIBUS and PROFINET Network Adapter–August 2013...
  • Page 14: How To Dismount From Din Rail

    Chapter 2. Installation 2.1.2 How to dismount from DIN Rail 1. Pull down the locking mechanism by using small flat screw driver as in the following figures. Figure 3: Pulling down the lock 2. Pull up the module to remove from the DIN rail. Figure 4: Pulling up the module PACSystems* RSTi PROFIBUS and PROFINET Network Adapter–August 2013 GFK-2746B...
  • Page 15: How To Mount And Dismount Network Adapter With Integrated Io

    Chapter 2. Installation 2.1.3 How to mount and dismount Network adapter with Integrated IO Figure 5: module mounting/dismounting instructions Release the DIN rail locking clip by pulling clip downward with a small-bladed screwdriver. The clip will click and lock into the open position. Install the module on the DIN rail firmly. Once module is in place on the DIN rail, push the clip upward to secure the module on the DIN rail.
  • Page 16: Installing And Removing Components

    Chapter 2. Installation Installing and Removing Components To plug in the module use a small-bladed screwdriver and push down the locking lever located at bottom of the module. Install the module on DIN rail firmly; push up the locking lever to lock. To pull out the RSTi module, push down the locking lever rail.
  • Page 17: Internal Bus/Field Power Contacts

    Chapter 2. Installation Internal Bus/Field Power Contacts Communication between the Network adapters and the IO module as well as system / field power supply of the bus modules is carried out via the internal bus. It is comprised of 6 data pins and 2 field power pins.
  • Page 18: Rsti Data Bus System

    Chapter 2. Installation 2.3.2 RSTi Data Bus System Figure 8: Interface between different modules ■ Network Adapter Module: The Network Adapter Module forms the link between the field bus and the field devices through IO Modules. The connection to different field bus systems can be established by each of the corresponding Network Adapter Modules: PROFIBUS, CANopen, DeviceNet, Ethernet/IP, CC-Link, MODBUS/Serial, MODBUS/TCP, PROFINET etc.
  • Page 19: Profibus Network Adapters

    Chapter 3. PROFIBUS Network Adapters PROFIBUS Network Adapters PROFIBUS Network Adapters include STXPBS001 and STXPBS* modules.  STXPBS001 The following are the features of STXPBS001:  STXPBS001 is connected with the PROFIBUS-DP by means of 9 Pin D-sub Connector.  It works as a slave in the Master/Slave environment.
  • Page 20: Stxpbs001

    Chapter 3. PROFIBUS Network Adapters STXPBS001 3.1.1 Interface The following figure shows the interface diagram for STXPBS001. Figure 9: PROFIBUS Network Adaptor Module: STXPBS001 The following table lists the pin numbers and their description for STXPBS001. Table 2: STXPBS001: Pin Description Pin Number Description Pin Number...
  • Page 21: Specifications

    Chapter 3. PROFIBUS Network Adapters 3.1.2 Specifications The following table describes the specifications of STXPBS001. Table 3: STXPBS001: Interface Specifications Item Specification Network Type PROFIBUS-DP Network Cable PROFIBUS-DP Special Cable Cable Length 1.2Km ~ 100m Maximum Station No. 99 Station (Include Master Scanner) Station Type PROFIBUS-DP Slave Expansion No.
  • Page 22 Chapter 3. PROFIBUS Network Adapters Table 4: STXPBS001: General Specifications Item Specification Supply voltage : 24Vdc nominal Supply voltage range : 11~28.8Vdc System Power Protection : Output current limit(1.5A) Reverse polarity protection Power Dissipation 60mA typical @24Vdc Current for I/O Module 1.5A @5Vdc Isolation DeviceNet to internal logic : Non-isolation...
  • Page 23: Stxpbs

    Chapter 3. PROFIBUS Network Adapters STXPBS* 3.2.1 Interface 3.2.1.1 STXPBS032 – Adapter with 32 pt Positive Logic Input The following figure shows the interface diagram for STXPBS032. Figure 10: PROFIBUS Network Adaptor Module: STXPBS032 Table 5: STXPBS032: Pin Description Pin Number Description Pin Number Description...
  • Page 24: Stxpbs132 - Adapter With 32 Pt Negative Logic Input

    Chapter 3. PROFIBUS Network Adapters 3.2.1.2 STXPBS132 – Adapter with 32 pt Negative Logic Input The following figure shows the interface diagram for STXPBS132. Figure 11: PROFIBUS Network Adaptor Module: STXPBS132 Table 6: STXPBS132: Pin Description Pin Number Description Pin Number Description 01-0 Input Channel 0...
  • Page 25: Stxpbs232 - Adapter With 32 Point Negative Logic Output

    Chapter 3. PROFIBUS Network Adapters 3.2.1.3 STXPBS232 – Adapter with 32 point Negative Logic Output The following figure shows the interface diagram for STXPBS232. Figure 12: PROFIBUS Network Adaptor Module: STXPBS232 Table 7: STXPBS232: Pin Description Pin Number Description Pin Number Description 01-0 Output Channel 0...
  • Page 26: Stxpbs332 - Adapter With 32 Point Positive Logic Output

    Chapter 3. PROFIBUS Network Adapters 3.2.1.4 STXPBS332 – Adapter with 32 point Positive Logic Output The following figure shows the interface diagram for STXPBS332. Figure 13: PROFIBUS Network Adaptor Module: STXPBS332 Table 8: STXPBS332: Pin Description Pin Number Description Pin Number Description 01-0 Output Channel 0...
  • Page 27: Stxpbs016 - Adapter With 16 Relay Output

    Chapter 3. PROFIBUS Network Adapters 3.2.1.5 STXPBS016 – Adapter with 16 relay output The following figure shows the interface diagram for STXPBS016. Figure 14: PROFIBUS Network Adaptor Module: STXPBS016 Table 9: STXPBS016: Pin Description Pin Number Description Pin Number Description 01-0 Relay Output 0 03- 0...
  • Page 28: Stxpbs116 - Adapter With 16 Relay Output Isolated

    Chapter 3. PROFIBUS Network Adapters 3.2.1.6 STXPBS116 – Adapter with 16 relay output isolated The following figure shows the interface diagram for STXPBS116. Figure 15: PROFIBUS Network Adaptor Module: STXPBS116 Table 10: STXPBS116: Pin Description Pin Number Description Pin Number Description 01-0 Relay Output 0...
  • Page 29: Stxpbs432 - Adapter With 16 Positive Logic In/16 Negative Logic Out

    Chapter 3. PROFIBUS Network Adapters 3.2.1.7 STXPBS432 – Adapter with 16 Positive Logic in/16 Negative Logic out The following figure shows the interface diagram for STXPBS432. Figure 16: PROFIBUS Network Adaptor Module: STXPBS432 Table 11: STXPBS432: Pin Description Pin Number Description Pin Number Description...
  • Page 30: Stxpbs532 - Adapter With 16 Negative Logic In/16 Negative Logic

    Chapter 3. PROFIBUS Network Adapters 3.2.1.8 STXPBS532 – Adapter with 16 Negative Logic in/16 Negative Logic The following figure shows the interface diagram for STXPBS532. Figure 17: PROFIBUS Network Adaptor Module: STXPBS532 Table 12: STXPBS532: Pin Description Pin Number Description Pin Number Description 01-0...
  • Page 31: Stxpbs824 - Adapter With 16 Positive Logic In/8 Relay Out

    Chapter 3. PROFIBUS Network Adapters 3.2.1.9 STXPBS824 – Adapter with 16 Positive Logic in/8 relay out The following figure shows the interface diagram for STXPBS824. Figure 18: PROFIBUS Network Adaptor Module: STXPBS824 Table 13: STXPBS824: Pin Description Pin Number Description Pin Number Description 01-0...
  • Page 32: Stxpbs924 - Adapter With 16 Negative Logic In/8 Relay Out

    Chapter 3. PROFIBUS Network Adapters 3.2.1.10 STXPBS924 – Adapter with 16 Negative Logic in/8 relay out The following figure shows the interface diagram for STXPBS924. Figure 19: PROFIBUS Network Adaptor Module: STXPBS924 Table 14: STXPBS924: Pin Description Pin Number Description Pin Number Description 01-0...
  • Page 33: Stxpbs825 - Adapter With 16 Positive Logic In/8 Relay Out Isolated

    Chapter 3. PROFIBUS Network Adapters 3.2.1.11 STXPBS825 – Adapter with 16 Positive Logic in/8 relay out isolated The following figure shows the interface diagram for STXPBS825. Figure 20: PROFIBUS Network Adaptor Module: STXPBS825 Table 15: STXPBS825: Pin Description Pin Number Description Pin Number Description...
  • Page 34: Stxpbs925 - Adapter With 16 Negative Logic In/8 Relay Out Isolated

    Chapter 3. PROFIBUS Network Adapters 3.2.1.12 STXPBS925 – Adapter with 16 Negative Logic in/8 relay out isolated The following figure shows the interface diagram for STXPBS925. Figure 21: PROFIBUS Network Adaptor Module: STXPBS925 Table 16: STXPBS925: Pin Description Pin Number Description Pin Number Description...
  • Page 35: Stxpbs* Specifications

    Chapter 3. PROFIBUS Network Adapters 3.2.2 STXPBS* Specifications Table 17: STXPBS*: Interface Specifications Item Specification Network Type PROFIBUS-DP Network Cable PROFIBUS-DP Special Cable Cable Length 1.2Km ~ 100m Maximum Station No. 99 Station (Include Master Scanner) Station Type PROFIBUS-DP Slave Expansion No.
  • Page 36 Chapter 3. PROFIBUS Network Adapters Table 18: STXPBS*: General Specifications Item Specification Supply voltage : 24Vdc nominal System Power Supply voltage range : 19.2~28.8Vdc Protection : Current limit, Reverse polarity protection Power Dissipation 50mA typical @24Vdc Current for I/O Module 0.4A @5Vdc Isolation System Power to internal logic: Non-isolation, Internal logic...
  • Page 37 Chapter 3. PROFIBUS Network Adapters Table 19: STXPBS* Input/Output/Relay Module Specifications Model STXPBS* Input Specification Number of 32 Points 16 Points 16 Points Input Positive Negative Positive Negative Positive Negative Positive Negative Type Logic Logic Logic Logic Logic Logic Logic Logic Indicates 1 LED/ 1 point...
  • Page 38: Led Indicators

    Chapter 3. PROFIBUS Network Adapters 3.2.3 LED Indicators 3.2.3.1 Module Status LED (MOD) Table 20: Module Status LED Color Status Function No Power No power is supplied to the unit. The unit is operating in normal Device Operational Solid Green condition.
  • Page 39: Io Module Status Led (I/O)

    Chapter 3. PROFIBUS Network Adapters 3.2.3.3 IO Module Status LED (I/O) Table 22: IO Module Status LED Color Status Function Not Powered Device has no IO module or may not No IO Module be powered RSTi bus is on-line but does not RSTi bus On-line, exchange I/O data.
  • Page 40: Dimensions

    Chapter 3. PROFIBUS Network Adapters 3.2.4 Dimensions 3.2.4.1 STXPBS001 Dimension The following figure displays the dimension for STXPBS001. Figure 22: Dimension for STXPBS001 3.2.4.2 STXPBS* Dimension The following figure displays the dimension for STXPBS*. Figure 23: Dimension for STXPBS* 3.2.4.3 Total IO The number of the module assembly that can be connected is 32 for STXPBS001 and 8 for STXPBS*.The maximum length is 426mmm and 179mm respectively.
  • Page 41: Profibus Communication Interface

    Chapter 3. PROFIBUS Network Adapters PROFIBUS Communication Interface 3.2.5 Figure 24: PROFIBUS Adapter Communication interface The following table describes the Signal Name and Description. Table 24: Signal name and Description Name Description RXD/TXD-P Receive/Transmit data-plus (B wire) Repeater control signal (direction control), RTS CNTR-P signal DGND...
  • Page 42: Choice Of Profibus Data Transfer Cable Type

    Chapter 3. PROFIBUS Network Adapters To prevent EMC interface from entering the device, the cable shield should be connected to the functional ground of the device (generally the electrically conductive case). This is done by connecting the cable shield to the metal case of the Sub-D connector and the functional ground over a larger area.
  • Page 43 Chapter 3. PROFIBUS Network Adapters The cable parameters specified for standard Type A bus cables result in the maximum length of each bus segment for the respective data transfer rate as shown in the below table. ■ Maximum Cable Lengths per Segments Table 26: Maximum Cable Lengths per Segments Baud rate 9.6 19.2...
  • Page 44: Profibus Module Configuration

    Chapter 3. PROFIBUS Network Adapters PROFIBUS Module Configuration 3.2.7 3.2.7.1 System and Field Power cable wiring Figure 25: system & field power connection 1. For safety, supply system power and field power should be separated.  System Power: for System & PROFIBUS communications ...
  • Page 45: Station Address And Quick Startup Mode Setup

    Chapter 3. PROFIBUS Network Adapters 3.2.7.2 Station Address and Quick Startup Mode Setup Station Address Setup for STXPBS001 Each PROFIBUS Adapter must have a unique address (from 1 to 99) so that it can be addressed independently from other nodes. The address 0 is reserved to identify a broadcast exchange.
  • Page 46 Chapter 3. PROFIBUS Network Adapters Station Address Setup for STXPBS Each PROFIBUS Adapter must have a unique Node Station address (from 0 to 99) so that it can be addressed independently from other nodes. The figure below shows Dip Switch #1~7 setting. Figure 27: DIP Switch ■...
  • Page 47: Adding Gsd File

    Choose the desired slave device or choose “Have Disk” to add other slave devices. Now click on “Toolchest”, choose “PROFIBUS Devices”, select the desired network adapter and hit F1 to see the contents of the GSD file. For latest GSD file, please visit GE-IP support site. Figure 30: Contents of GSD file GFK-2746B PACSystems* RSTi PROFIBUS and PROFINET Network Adapter–August 2013...
  • Page 48: Configuring An I/O Station For Profibus Communication

    Configuring an I/O Station for PROFIBUS Communication 3.2.8 To configure I/O station, add a GE-IP PROFIBUS master module at the desired slot in the Rx3i or 90-30 Proficy Machine Edition project. Ensure that you have the latest GSD file imported. Right click on the master module and choose “Add Slave”. Select “STXPBS001” for PROFIBUS Network Adapter or STXPBS for all-in-one PROFIBUS Network Adapter.
  • Page 49 Fault” should be set to “Power restart” for this parameter to behave appropriately. Note that in order to observe a “loss of Device” in IO fault table , the “slave status Fault table entries” must be set to “true” in the GE IP PROFIBUS master settings tab as shown below: GFK-2746B PACSystems* RSTi PROFIBUS and PROFINET Network Adapter–August 2013...
  • Page 50 Chapter 3. PROFIBUS Network Adapters a. PROFIBUS Communication: Last input values will not hold. NET LED will be blinking Green. Network adaptor communication with master stops. IO LED will be red and fault “Loss of device' logged in I/O fault table. b.
  • Page 51: Dpv1 Services To Read Write Network Adapter Configuration Parameters

    Chapter 3. PROFIBUS Network Adapters 3.2.8.1 DPV1 services to read write network adapter configuration parameters. The PROFIBUS network adapter also supports DPV1 service. The details are as below: 3.2.8.2 DPV1 Write service  Slot#=0, Index 1: Write STXPBS001 extension parameter(2Byte) ...
  • Page 52 Chapter 3. PROFIBUS Network Adapters Command Reaction to DP Clear Action Word data Restart on Bus Bus Fault Format fault Binary 00000001 01: Clear Input 00: Bus Stop IO 01 11 00010001 data fault action 01:MOTOROLA 01: auto reset 00000000 01: Clear Input 01: Bus Run ( 00 05...
  • Page 53: Dpv1 Read Service

    Chapter 3. PROFIBUS Network Adapters 3.2.8.3 DPV1 Read service  Slot#=0, Index 1: Read STXPBS001 extension parameters (2Byte)  Slot#1~32, Index 1: Read parameter for an IO module.  Slot#1~32, Index 2: Read memory data from an IO module.  Slot#=0, Index 254: Read vendor code from EEPROM directly.
  • Page 54: I/O Process Image Map

    Chapter 3. PROFIBUS Network Adapters In order to minimize cable reflections and ensure a defined noise level on the data lines, the data transfer cable must be terminated at both ends with a terminating resister combination as follows: Figure 32: Terminating Resistor Combination I/O Process Image Map 3.2.9 An IO module may have three types of data: I/O data, configuration parameter, and memory...
  • Page 55: Example Of Input Process Image Map

    Chapter 3. PROFIBUS Network Adapters The following figure shows the data flow of process image between network adapter and IO modules for STXPBS*. Figure 34: STXPBS*: Data flow between Network Adapter and IO Modules 3.2.9.1 Example of Input Process Image Map Input image data depends on slot position and IO Module data type.
  • Page 56 Chapter 3. PROFIBUS Network Adapters The following table lists the slot number and module description. Table 28: Slot number and Module Description Slot Address Module Description STXPBS032 32-discrete input (4byte) 4-discrete Input (4 bit) 16-discrete Input (2 byte) 4-analog Input (4 word) 2-analog output (2 word) ■...
  • Page 57: Example Of Output Process Image Map

    Chapter 3. PROFIBUS Network Adapters 3.2.9.2 Example of Output Process Image Map Figure 36: Slot Configuration The following table lists the slot number and module description. Table 30: Slot number and Module Description Slot Address Module Description STXPBS032 32-discrete input (4 byte) 2-discrete Input (2 bit) 4-discrete Input (4 bit) 16-discrete output (2 byte)
  • Page 58 Chapter 3. PROFIBUS Network Adapters ■ Output Process Image Mode (Uncompressed Output Processing Data) Table 31: Output Process Image Mode Byte Slot # Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Byte 0 0 (AT2) 1st output byte (Base IO) Byte 1...
  • Page 59: Stxpbs001: Dpv1 Service Specification

    Chapter 3. PROFIBUS Network Adapters STXPBS001: DPV1 Service Specification Supported Service 3.3.1 ■ MSAC1 Read ■ MSAC1 Write ■ MSAC2 Initiate / MSAC2 Abort ■ MSAC2 Read ■ MSAC2 Write MSAC1 Read (PROFIBUS-DP Extensions to EN 50170) 3.3.2 ■ MSAC1 Read Request Parameter Description Remote Address...
  • Page 60: Msac1 Write (Profibus-Dp Extensions To En 50170)

    Chapter 3. PROFIBUS Network Adapters MSAC1 Write (PROFIBUS-DP Extensions to EN 50170) 3.3.3 ■ MSAC1 Write Request Parameter Description Remote Address Slave Address (0~99) Slot Number (0~32), Slot Number 0: STXPBS001 1: Parameter Index 2: Memory Length 1~128 1. Parameter 2.
  • Page 61: Msac2 Initiate (Profibus-Dp Extensions To En 50170)

    Chapter 3. PROFIBUS Network Adapters MSAC2 Initiate (PROFIBUS-DP Extensions to EN 50170) 3.3.4 ■ MSAC2 Initiate Request Parameter Description C_Ref PROFIBUS-DP Extensions to EN50170 Rem_Add Slave station address(0~99) Send Timeout PROFIBUS-DP Extensions to EN50170 Features_Supported_1 0x03 Features_Supported_2 Reserved Profile_Features_Supported_1 PROFIBUS-DP Extensions to EN50170 Profile_Features_Supported_2 PROFIBUS-DP Extensions to EN50170 Profile_Ident_Number...
  • Page 62: Msac2 Abort (Profibus-Dp Extensions To En 50170)

    Chapter 3. PROFIBUS Network Adapters MSAC2 Abort (PROFIBUS-DP Extensions to EN 50170) 3.3.5 ■ MSAC2 Initiate Request Parameter Description C_Ref PROFIBUS-DP Extensions to EN50170 Subnet Slave station address Instance PROFIBUS-DP Extensions to EN50170 PROFIBUS-DP Extensions to EN50170 Reason_code MSAC2_Read,MSAC2_Write MSAC2 Read (PROFIBUS-DP Extensions to EN 50170) 3.3.6 ■...
  • Page 63: Msac2 Write (Profibus-Dp Extensions To En 50170)

    Chapter 3. PROFIBUS Network Adapters MSAC2 Write (PROFIBUS-DP Extensions to EN 50170) 3.3.7 ■ MSAC2 Write Request Parameter Description Remote Address Slave Address (0~99) Slot Number (0~32), Slot Number 0: STXPBS001 1: Parameter Index 2: Memory Length 1~128 1. Parameter 2.
  • Page 64: Error Decode (Profibus-Dp Extensions To En 50170)

    Chapter 3. PROFIBUS Network Adapters Error Decode (PROFIBUS-DP Extensions to EN 50170) 3.3.8 ■ 0~127 : Reserved ■ 128 : DPV1 ■ 129~253 : Reserved ■ 254 : FMS ■ 255 : HART Error Code_1 (PROFIBUS-DP Extensions to EN 50170) 3.3.9 ■...
  • Page 65: Diagnostics

    Chapter 3. PROFIBUS Network Adapters Diagnostics 3.3.10 Byte Item Description Station status 0 PROFIBUS Standard Diagnostic Station status 0 Station status 0 Master Address PNO Ident Number High PNO Ident Number Low ID Diagnostic Header Extended Diagnostic (ID Related Diagnostic) Diagnostic allocation (Slot0~7) Diagnostic allocation (Slot8~15) Diagnostic allocation (Slot16~23)
  • Page 66 Chapter 3. PROFIBUS Network Adapters ■ Device Related Diagnostic (Status message byte)  0x21: No response from expansion slot  0x22: Response error (Type)  0x23: Response error (Slot Number)  0x24: Response error (Length)  0x25: Response error (Protocol) ...
  • Page 67: Profinet Network Adapter

    Chapter 4. PROFINET Network Adapter PROFINET Network Adapter STXPNS001 Interface 4.1.1 The following figure shows the interface design for STXPNS001. Figure 37: PROFINET Network Adaptor Module: STXPNS001 The following table lists the pin numbers and their description for STXPNS001. Table 32: STXPNS001: Pin Description Pin Number Description Pin Number...
  • Page 68: Stxpns001 Specifications

    Chapter 4. PROFINET Network Adapter STXPNS001 Specifications 4.1.2 The following table describes the Interface Specifications and General Specifications of STXPNS001. Table 33: STXPNS001: General and Environment Specifications Items Specification Communication Interface Specifications Protocol PROFINET IO RT Station type PROFINET IO Device Topology Line or Star topology Number of Nodes...
  • Page 69: Stxpns001 Led Indicators

    Chapter 4. PROFINET Network Adapter STXPNS001 LED Indicators 4.1.3 4.1.3.1 Module Status LED (MOD) Table 34: STXPNS001: Module Status LED Color Status Function Power off No power is supplied to the unit. H/W Fault The unit has occurred Invalid boot image header unrecoverable fault in self-testing.
  • Page 70: Io Module Status Led (I/O)

    Chapter 4. PROFINET Network Adapter 4.1.3.3 IO Module Status LED (I/O) Table 36: STXPNS001: IO Status LED Color Status Function Not Powered Device has no IO module or may not be powered No IO Module RSTi Bus is on-line but does not exchanging I/O data Flashing Green RSTi Bus On-line...
  • Page 71: Stxpns001 Dimension

    Chapter 4. PROFINET Network Adapter STXPNS001 Dimension 4.1.4 The following figure displays the dimension for STXPNS001. Figure 38: Dimension for STXPNS001 4.1.4.1 Total IO The number of the module assembly that can be connected is 32. The maximum length is 426mm.
  • Page 72: Profinet Communication Interface

    Chapter 4. PROFINET Network Adapter 4.1.5 PROFINET Communication Interface 4.1.5.1 PROFINET Communication Interface for STXPNS001 Figure 39: Shielded RJ-45 Socket The following table describes the Signal Name and Description. Table 39: Signal name and Description RJ-45 Signal Name Description Transmit + Transmit - Receive + Receive -...
  • Page 73: Profinet Module Configuration

    Chapter 4. PROFINET Network Adapter 4.1.6 PROFINET Module Configuration 4.1.6.1 System and Field Power cable wiring Figure 40: System power & Field power connections 1. For safety, supply system power and field power should be separated. a. System Power: for System & PROFINET communications b.
  • Page 74: Profinet Parameterization By Rotary Switch

    Chapter 4. PROFINET Network Adapter 4.1.6.2 PROFINET Parameterization by Rotary Switch Table 40: Rotary switch: Values and Description Value Description Factory Setting  Name of station : STXPNS001 Name of the station will be  read from flash memory. IP address:192.168.0.254 ...
  • Page 75 In this case, the second device has the extension "-1", the third one has the extension "- 2", and so on. ■ Communication Speed Setting  Refer to GEIP PROFINET master module settings to change the communication speed (GE-IP PROFINET Controller User Manual- GFK-2571). GFK-2746B PACSystems* RSTi PROFIBUS and PROFINET Network Adapter–August 2013...
  • Page 76: Stxpns001 Parameter Settings

    Chapter 4. PROFINET Network Adapter 4.1.6.3 STXPNS001 Parameter Settings The following table describes the STXPNS001 parameter settings. Table 41: STXPNS001: Parameter Setting and Description Parameter Setting Description Word data type MOTOLORA * Big Endian format(MSB-LSB) INTEL Little Endian format(LSB-MSB) Stop action Clear output image to 0 * All outputs are set to 0.
  • Page 77: Configuring An I/O Station For Profinet Communication

    Configuring an I/O Station for PROFINET Communication 4.1.7 To configure I/O station, add a GE-IP PROFINET master module at the desired slot in the RX3i PME project. Ensure that you have the latest GSDML file imported. Right click on master module and choose “Add IO Device”. Select “STXPNS” for PROFINET Network adapter and Select “OK”.
  • Page 78 Chapter 4. PROFINET Network Adapter In order to add IO modules in this node, right click on recently added network adapter node and select “Change Module List”; a pop up window will open as shown below: Figure 43: Change Module List Now start adding the IO modules as per the physical setup;...
  • Page 79 Chapter 4. PROFINET Network Adapter Choose “STXPNS Parameters” for parameter settings. There are three options: 1. Word Data Format: The options are MOTOROLA & INTEL. MOTOROLA format is big endian; therefore ensure that the IO modules connected to the node are configured with "False"...
  • Page 80 Chapter 4. PROFINET Network Adapter 3. Reaction to Bus Error: If Bus error is detected, the behavior of the network module will be as per the options selected below: a. Clear Input Image: Input values will be zero. NET LED will be Green. Network adaptor communication with master intact.
  • Page 81: Diagnostics

    Appendix A. Diagnostics Diagnostics How to Diagnose when Device Cannot Communicate with the Network ■ Verify that cable connections are correct. ■ If terminator resistor is not installed, install terminator resistor. Check location of terminator resistor. ■ Ensure there are no duplicate node addresses. ■...
  • Page 82: Product List

    Appendix B. Product List Product List Table 42: Product List Production Description ID(hex) Number Status Digital Input Modules ST-1114 4 Points, Sink(Positive), 5Vdc 41 00 01 Active ST-1124 4 Points, Source(Negative), 5Vdc 41 00 02 Active ST-1214 4 Points, Sink(Positive), 12V/24Vdc 41 00 03 Active ST-1218...
  • Page 83 Appendix B. Product List Production Description ID(hex) Number Status Analog Input Modules ST-3114 4 Channels, Current, 0~20mA, 12bit 41 43 1C Active ST-3118 8 Channels, Current, 0~20mA, 12bit 41 47 82 Active ST-3134 4 Channels, Current, 0~20mA, 14bit 41 43 1E Active ST-3214 4 Channels, Current, 4~20mA, 12bit...
  • Page 84 Appendix B. Product List Production Description ID(hex) Number Status Special Modules 1 Channel, High Speed Counter, 5V Input Active ST-5101 C1 01 05 34 ST-5111 1 Channel, High Speed Counter, 24V Input C1 01 05 39 Active 2 Channel, High Speed Counter, 24V Sink Active ST-5112 C1 01 07 4D...
  • Page 85: Product Certifications And Installation Guidelines For Conformance

    In no event will GE be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
  • Page 86: Government Regulations

    AC power source. The PACSystems RSTi family of products has been tested and found to meet or exceed the requirements of U.S. (47 CFR 15), Canadian (ICES-003), Australian (AS/NZS 3548), and European (EN 61000-6-4:2007) regulations for Class A digital devices when installed in accordance with the guidelines noted in this manual.
  • Page 87: Environmental Specifications

    Appendix C. Product Certifications and Installation Guidelines for Conformance Environmental Specifications C.5.1 PROFIBUS STXPBS001 & STXPBS* Table 43: Environmental specification for STXPBS001 Items Specification Operating Temperature 0℃ to 55℃ for UL applications ; 0℃ to 60℃ for non-UL applications Storage Temperature Storage -40℃...
  • Page 88 PACSystems* RSTi PROFIBUS and PROFINET Network Adapter–August 2013 GFK-2746B...
  • Page 89 IO, 15 STXPNS001 Dimension, 71 Network Topology, 10 FCC notice, 86 Output Process Image Map for STXPBS*, 57 Features PACSystem Documentation, 11 PACSystems RSTi, 11 Parameter settings STXPBS*, 19 STXPNS001, 76 STXPBS001, 19 Product List, 82 Government regulations, 86 PROFIBUS Communication Interface, 41...
  • Page 90 1-800-433-2682 or 1-434-978-5100 www.ge-ip.com Global regional phone numbers are available on our web site www.ge-ip.com ©2013 GE Intelligent Platforms, Inc. All Rights Reserved *Trademark of GE Intelligent Platforms, Inc. All other brands or names are property of their respective holders. GFK-2746B...

Table of Contents