Set Up Error Messages - Bosch rexroth CS660 Calibration Manual

Spreader controller
Hide thumbs Also See for rexroth CS660:
Table of Contents

6 Set Up Error Messages

Error Messages
#
Suggested Solution
01-BLAST TOO LONG
1
Blast held too long
02-LIQ BLST TOO LONG
2
Liquid blast held too long
03-OVER SPEED
3
Slow down, reset max speed
04-ERR SPN OUTPUT
4
Check cables, check coil
05-ERR CONV OUTPUT
5
Check cables, check coil
06-ERR CRS1 OUTPUT
6
Check cables, replace coil
07-ERR CRS2 OUTPUT
7
Check cables, replace coil
08-NO GRANULAR DET
8
Load material, check sensor
09-NO LIQUID DET
9
Load material, check sensor
10-NO GROUND SPEED
10 Check cable/sensor
11-NO CONV FEEDBACK 11 Check cable/sensor
12-NO WET FEEDBACK
12 Check cable/sensor
13-NO LIQ FEEDBACK
13 Check cable/sensor
Warning Messages
21-UNLOAD NOT ALLOWED
22-SYSTEM ERROR !!!
23-NO RC,CHK FUSE/CONNECTION
24-LIQUID BOOM OPERATION ERROR
25-NO JOY1,CHK CONNECTION
26-NO JOY2,CHK CONNECTION
27-NO GATE POS SENSOR
28-GATE CLOSED
29-NO SIMULATE
30-SPN UNDER APP
31-SOLID UNDER APP
32-PREWET UNDER APP
33-LIQ UNDER APP
37-GND SPD CALIBRATION
38-SPINNER CALIBRATION
39-CONVEYOR CALIBRATION
40-PREWET CALIBRATION
41-LIQ CALIBRATION
42-SPN CAL: WRONG CTRL MODE
43-CNV CAL:WRONG CTRL MODE
44-PREWET CAL:WRONG CTRL MODE 44 Auto-null or calibration not allowed
45-LIQ CAL:WRONG CTRL MODE
46-CRS CNV CAL:WRONG MODE
47-CALIBRATION ERROR
48-CALIBRATION ERROR
xx-CALIBRATION ERROR
Bosch Rexroth Canada I March 2021 ı Revision 3.0
25/27
#
Suggested Solution
21 Vehicle needs to be stationary
22 Reboot, or re-flash
23 Comm failure between display and RC
24 Need at least one boom to work
25 Comm failure between RC and Joy 1
26 Comm failure between RC and Joy 2
27 Check gate sensor, cable break
28 Gate closed in READBACK mode
29 Speed Simulation mode stopped
30 Spinner not able to reach desired RPM
31 Rate or spd too hi, incorrect calib
32 Rate or spd too hi, incorrect calib
33 Rate or spd too hi, incorrect calib
37 Too few or no pulses, recalibrate
38 Bad or no sensor
39 Bad or no sensor
40 Too few pulses, or sensor failed
41 Too few pulses, or sensor failed
42 Auto null not allowed for MAN mode
43 Auto-null or calibration not allowed
45 Check Anti-icing or CrsCnv modes
46 Check Cross-Conv mode setting
47 Check sensor, recalibrate
48 Check sensor, recalibrate
49
Check sensor, recalibrate
.
.
70
Table of Contents
loading

This manual is also suitable for:

Rexroth cs661

Table of Contents