Overview of electrical connections
for external and internal actuators
Item
Power supply
See
"5.3 To connect the main power
supply" [ 4  13].
Remote outdoor
See
"5.4 To connect the remote outdoor
sensor" [ 4  16].
sensor
Shut-off valve
See
"5.5 To connect the shut-off
valve" [ 4  16].
Electricity meter
See
"5.6 To connect the electricity
meters" [ 4  17].
Domestic hot water
See
"5.7 To connect the domestic hot water
pump" [ 4  17].
pump
Alarm output
See
"5.8 To connect the alarm
output" [ 4  18].
Space cooling/heating
See
"5.9 To connect the space cooling/
operation control
heating ON/OFF
Changeover to
See
"5.10 To connect the changeover to
external heat source
external heat
control
Power consumption
See
"5.11 To connect the power
digital inputs
consumption digital
Safety thermostat
See
"5.12 To connect the safety thermostat
(normally closed
Brine low pressure
See
"5.13 To connect the brine low
switch
pressure
Thermostat for passive
See
"5.14 To connect the thermostat for
cooling
passive
LAN adapter
See
"5.15 LAN
connections
Room thermostat
See:
(wired or wireless)
▪ Installation manual of the room
▪ Addendum
Wires for wired room thermostat: (3
for cooling/heating operation; 2 for
heating only operation)×0.75 mm²
Wires for wireless room thermostat: (5
for cooling/heating operation; 4 for
heating only operation)×0.75 mm²
Maximum running current: 100 mA
For the main zone:
▪ [2.9] Control
▪ [2.A] Thermostat type
For the additional zone:
▪ [3.A] Thermostat type
▪ [3.9] (read-only) Control
EGSAH/X06+10DA9W(G)
Daikin Altherma 3 GEO
4P569811-1C – 2020.07
Description
output" [ 4  18].
source" [ 4  19].
inputs" [ 4  20].
contact)" [ 4  20].
switch" [ 4  21].
cooling" [ 4  22].
adapter" [ 4  22].
thermostat (wired or wireless)
book
for
optional
equipment
Item
Heat pump convector
See:
▪ Installation manual of the heat
▪ Addendum
Wires: 4×0.75 mm²
Maximum running current: 100 mA
For the main zone:
▪ [2.9] Control
▪ [2.A] Thermostat type
For the additional zone:
▪ [3.A] Thermostat type
▪ [3.9] (read-only) Control
Remote indoor sensor
See:
▪ Installation manual of the remote
▪ Addendum
Wires: 2×0.75 mm²
[9.B.1]=2 (External sensor = Room)
[1.7] Room sensor offset
Current sensors
See the installation manual of the
current sensors.
Wires: 3×2. Use part of the cable
(40 m) delivered as accessory.
[9.9.1]=3 (Power consumption
control = Current sensor)
[9.9.E] Current sensor offset
Human Comfort
See:
Interface
▪ Installation and operation manual of
▪ Addendum
Wires: 2×(0.75~1.25 mm²)
Maximum length: 500 m
[2.9] Control
[1.6] Room sensor offset
5.3

To connect the main power supply

Use one of the following layouts to connect the power supply (for
details of C1~C5, see below the table):
#
Layout
1 Single cable power supply (= combined
power supply)
C1
C1: Power supply for the backup heater,
and the rest of the unit (1N~ or 3N~)
5 Electrical installation
Description
pump convectors
book
for
optional
equipment
indoor sensor
book
for
optional
equipment
the Human Comfort Interface
book
for
optional
equipment
Open the unit
Not necessary
(connection to
factory-mounted
cable outside of the
unit)
Installation manual
(a)
13