User Programming Mode - GE Concord 4 Installation Manual

Hide thumbs Also See for Concord 4:
Table of Contents

User programming mode

The user programming mode allows you to view system version information and
program system settings. You can enter user programming from an alphanumeric or
fixed display touchpad by using the system or partition master code. The default
system master code is 1234. To enter user programming mode, press 9, code. The
display shows TIME AND DATE. The default settings are shown in brackets in the
table where applicable.
Table 13: User programming menus
Time and date
User codes
Options
Set up schedules
Attach schedule to
events
Concord 4 Installation Manual
Time
Date
Regular user
Partition master
System master
Downloading [On]
Touchpad brightness [2]
Volume [4]
Voice chime [On]
Chime on close [Off]
Schedule 00 to 15
Latchkey opening
Latchkey closing
Exception opening
Exception closing
Lights 1 to 9
Output 1 to 6
Arming
User 00
Direct bypassing [Off]
Remote access [Off]
System test [Off]
Latchkey report [Off]
Partition assign [1]
Partition master code [None]
System master code [1234]
Start time [00:00]
Stop time [00:00]
Monday [Off]
Tuesday [Off]
Wednesday [Off]
Thursday [Off]
Friday [Off]
Saturday [Off]
Sunday [Off]
Schedule 00 to 15 [Off]
Schedule 00 to 15 [Off]
Schedule 00 to 15 [Off]
Schedule 00 to 15 [Off]
Schedule 00 to 15 [Off]
Schedule 00 to 15 [Off]
Schedule 00 to 15 [Off]
Chapter 3: Programming
79
Table of Contents
loading