Chapter 3: Programming

Touchpad options menu

Touchpad options - global settings
Latchkey zones
Shortcut: 0500
Default: None
Touchpad options - partition 1 to 6 settings
Fire panic
Shortcut: 0510 to 0560
Default: On
Auxiliary panic
Shortcut: 0511 to 0561
Default: On
Police panic
Shortcut: 0512 to 0562
Default: On
Keyfob (keychain TP)
arm
Shortcut: 0513 to 0563
Default: Off
Star is no delay
Shortcut: 0514 to 0564
Default: Off
58
This setting defines the range of keyfobs that will function as latchkey users
(1 to 96). The value you enter in this section may be any valid zone number.
When you enter a zone number, all zones at or below that zone number
function as latchkey users. For example, if you enter 5, any keyfobs learned
into zones 1 to 5 will be latchkey users and all others (6 to 96) will not.
To delete or disable latchkey zones, with the display showing LATCHKEY
ZONES nnn (current setting), press D.
This setting determines whether touchpad fire panic buttons are enabled
(on) or disabled (off).
This setting determines whether touchpad auxiliary panic buttons are
enabled (on) or disabled (off).
This setting determines whether touchpad police panic buttons are enabled
(on) or disabled (off).
When this setting is on, pressing the Lock button on keyfob arms the system
directly to away with no delay. When this setting is off, each key press
increments the arming level (for example, from off to stay, from stay to
away).
This setting determines whether the keyfob Star button controls an output
(off) or the no delay feature (on).