Troubleshooting; Localizing And Remedying Short Circuits - Bosch rexroth ActiveMover Assembly Instructions Manual

Hide thumbs Also See for rexroth ActiveMover:
Table of Contents

176/188 Troubleshooting

Bosch Rexroth AG, MIT: ActiveMover, 3 842 564 874/2021-04
11 Troubleshooting
This chapter is used for troubleshooting and repair on the ActiveMover for qualifi ed
and trained service personnel.
The AMpro confi guration program is absolutely necessary to search for and rectify
other system errors.
Troubleshooting options can be found in the AMpro confi guration program help
function.

11.1 Localizing and remedying short circuits

Errors
Localization and remedy
Short-circuit between
The short circuit may be between the motor cable connection (28 V)
motor cable connection
and the connection motor cable (0 V) or between the motor cable
(28 V) and motor cable
(28 V) and housing (section/curve modules) connection.
connection (0 V) or
1. Loosen and isolate one side of the ground connection line in the
housing (section/curve
modules)
2. Now measure the resistance between the motor cable connection
3. Disconnect the motor cable (28 V) at each end of the system.
4. Measure the resistance of every half of the system. The short circuit
5. Loosen the motor cable (28 V) connection in the middle of the half
6. Repeat step 4.
7. Repeat this until you have localized the section/curve module with
curve module to which the control cabinet is connected.
(28 V) and the motor cable connection (0 V).
R = ∞
The short circuit is located between the motor cable
connection (28 V) and the housing (section/curve
modules).
R < 5 Ω
The short-circuit is located between the motor
cable connection (28 V) and the motor cable
connection (0 V).
This divides the system electrically into two parts.
is located in the half of the system with a resistance of < 5 Ω.
with the short-circuit.
the short-circuit.
557 186-133