Operating Parameters; Departure Delay; St , 2 Nd And 3 Rd Stage And Delay Final - Ugin PROGRAMIX 50 Instructions For Use Manual

Burnout furnace
Table of Contents
Instructions for use (rev 031121) - En

5.2. OPERATING PARAMETERS

- To program the operating parameters, press key
- When the program number blinking (display No.2), enter the data with keys
- To switch to another parameter, use the
- When you have programmed all the parameter, "lock" the program by pressing key

5.3. DEPARTURE DELAY

This timer function is used to delay the beginning of the firing cycle: from 0 hours to 99 hours and 59 minutes.
A count-down before start time is displayed on the control panel (n° 3).
Should you not wish to use this function, set the parameter at 0h 0min, heating will begin immediately (or
use the
key after pressing the
st
nd
rd
5.4. 1
, 2
AND 3
1st STAGE
o
Rate No. 1: STOP – from 1 to 15°C/min - FULL
The heating rate is the heat rise per unit time (rate of rise). There are three positions:
- STOP (the furnace stops heating): this is only used when the next stage is at a Iower temperature.
- 1 to 15°C/min:
be lower than that value, especially in the higher temperature ranges, or if the muffle is weIl Ioaded
(several cylinders inside the muffle).
- ''FULL'': this position corresponds to the maximum furnace output: the heat rise rate is no longer
regulated.
o
st
1
stage temperature: from 0 to 1200°C
Temperature setting for the 1
o
Hold time from 0 to 240 min
Hold time for the temperature of the 1
▪ 2
nd
STAGE
o
Rate No. 2 (RP 2): from 1 to 15°C/min – FULL - STOP
Heat rise to reach the second stage. The principle is the same as for heating rate No. 1, except that the
programmed values may differ.
o
nd
2
stage temperature: from 0 to 1200°C
Temperature setting for the 2
o
Hold time from 0 to 240 min
Hold time for the temperature of the 2
UGIN DENTAIRE
STAGE AND DELAY FINAL
h
eating is regulated and will not rise above the programmed value. However, it may
st
stage.
st
stage.
nd
stage.
nd
stage.
key.
touch control).
PROGRAMIX 50 - 100
and
again.
11
Table of Contents
loading

This manual is also suitable for:

Programix 100

Table of Contents