3.1.2 Wall mounting

The installation location must be suitable for con-
trolling the heating system or heating circuit.
The accuracy of the FW 100 is dependent upon
the installation location.
Any radiator in the same room as the FW 100
should not have a thermostatic radiator valve fit-
ted.
The FW 100 should be installed so that the over-
all temperature of the property is monitored, for
example, hallways or landings and not be
installed in a living room or room with supple-
mentary heating.
B Select the installation location.
35 mm
134 mm
119 mm
Fig. 8
The mounting surface on the wall
should be level.
0,3 m
0,3 m
0,6 m
1,2 - 1,5 m
6 720 612 481-03.1R
6 720 617 763 (2008/09)
Installation (for installers only)
B Remove the top section and slide cover from
the base.
2.
Fig. 9
1.
3.
13