[Data Cloning] - Panasonic PT-RZ990 Operating Instructions Manual

Table of Contents
[SIGNAL INFORMATION]
*1 The temperature status is indicated with text color (green/yellow/red) and bar scale. Use the projector within the range that the indication is
green.
*2 Only for PT-RZ990 / PT-RZ890
*3 [CONSOLIDATED RUNTIME] can be obtained with the following calculation formula. Values obtained by the calculation formula contain a
slight error.
A x 1.0 + B x 0.8 + C x 0.5 + D x 0.3 + E x 0.2
f A: Runtime of the light source with [OPERATING MODE] set to [NORMAL], [QUIET1], [QUIET2], [USER1], [USER2], or [USER3]
f B: Runtime of the light source with [OPERATING MODE] set to [ECO]
f C: Runtime of the light source with [OPERATING MODE] set to [LONG LIFE1]
f D: Runtime of the light source with [OPERATING MODE] set to [LONG LIFE2]
f E: Runtime of the light source with [OPERATING MODE] set to [LONG LIFE3]
Note
f E-mail containing the status can be sent to the E-mail address (up to two addresses) set in "[E-mail set up] page" ( x page 188) by pressing
the button while the [STATUS] screen is displayed.
f Some items in [SIGNAL INFORMATION] may be displayed and others not displayed, depending on the signal being input.
f If any abnormality has occurred on the projector, press the button while the [STATUS] screen is displayed to display the detail
screen of the error information.
f For details on the contents displayed in [SELF TEST], refer to "[SELF TEST] indications" ( x page 208).

[DATA CLONING]

Perform the operations of the data cloning function. Data such as the settings and adjustment values of the
projector can be copied to multiple projectors via LAN.
Setting the password of the administrator account ( x page 168) is required for using the data cloning function of
the projector.
r Data that cannot be copied
The following settings cannot be copied. Set these in each projector.
f The [PROJECTOR SETUP] menu → [PROJECTOR ID]
f The [PROJECTOR SETUP] menu → [DATE AND TIME] → [ADJUST CLOCK]
f The [PROJECTOR SETUP] menu → [DATA CLONING] → [WRITE PROTECT]
f The [SECURITY] menu → [SECURITY PASSWORD]
f The [NETWORK] menu → [WIRED LAN]
f The [NETWORK] menu → [PROJECTOR NAME]
f The [NETWORK] menu → [ADMINISTRATOR ACCOUNT]
f The [NETWORK] menu → [PJLink] → [PJLink PASSWORD]
f Security password
f Control device password
f Password set in "[Set up password] page" ( x page 192) of the web control screen
f "[E-mail set up] page" ( x page 188) in the web control screen
Chapter 4 Settings — [PROJECTOR SETUP] menu
[INPUT]
[SIGNAL FORMAT]
[SIGNAL FREQUENCY]
[SYNC.STATE]
[V.SYNC WIDTH]
[SCAN TYPE]
[TOTAL DOTS]
[DISPLAY DOTS]
[TOTAL LINES]
[DISPLAY LINES]
[SAMPLING]
[SIGNAL LEVEL]
[BIT DEPTH]
[HDCP STATUS]
Conversion formula for [CONSOLIDATED RUNTIME]
Displays the input terminal used for the projected image.
Displays the format of the input signal.
Displays the frequency of the input signal.
Displays the sync polarity of the input signal.
Displays the vertical sync signal pulse width of the input signal.
Displays the scan type of the input signal.
Displays the total dot count of the input signal.
Displays the number of input signal display dots.
Displays the total line count of the input signal.
Displays the number of input signal display lines.
Displays the sampling information of the input signal.
Displays the signal level of the input signal.
Displays the gradation of the input signal.
Displays the HDCP status of the input signal. The content of display
is as follows.
[HDCP2.2]: When protected with HDCP 2.2
[HDCP1.X]: When protected with HDCP 1.X
[NONE]: When not protected with HDCP
ENGLISH - 153