6�5 Switching System Installation - Bosch MKK-040 Instructions Manual

Linear modules
Table of Contents
14/62
Bosch Rexroth AG
Switching system MKK, MKR, MLR
6.5
Switching system installation
NOTES
Risk of collision due to incorrect assembly of the switching system!
Damage to product, adjoining structure and workpieces.
Prerequisite for the installation of the switching system is the fastening of the linear module frame.
f
Install the entire switching system on one side of the product (recommendation).
f
Move the carriage by hand to check for potential collision with the carriage or a mounted workpiece.
f
Magnetic sensor / magnetic field sensor
The switch activator is a magnet that is built into the carriage (no switching cam necessary). The switch
activation points can be positioned anywhere along the stroke. ! 6.5.12
6.5.1
Overview
1.
Socket and plug
2.
Mechanical switch with attachments
3.
Proximity sensor with additional components
4.
Switching cam (for mechanical and proximity switches)
5.
Mounting channel / cable channel
6.
Magnetic field sensor with fixed potted cable (Reed/Hall sensor (for mounting channel))
7.
Assembly magnetic sensor with plug and sensor mount
7a: Magnetic sensor
7b: Sensor mount incl. set screws (loose) and square nut
7c: Cable holder (3 pcs) incl. set screw (loose)
7d: Male connector M8x1, 3-pin
8.
Magnetic sensor with M8x1 plug
9.
Clamping screw
10.
Sliding block
Fig� 9:
Overview (pos. 1-5)
Further information on pos. 1-5 ! 6.5.10 / 6.5.11
Linear modules MKK/MKR-xxx-NN-3 | R320103169/2020-08
2
1
X
5
4
3
Table of Contents
loading