Allen-Bradley MSR127 Installation Instructions

Allen-Bradley MSR127 Installation Instructions

Monitoring safety relays

Quick Links

Installation Instructions
Original Instructions
MSR127 Minotaur Monitoring Safety Relays
Catalog Number 440R-N23124, 440R-N23125, 440R-N23126, 440R-N23127, 440R-N23128, 440R-N23129, 440R-N23129M, 440R-N23130,
440R­N23131, 440R-N23132, 440R-N23132S, 440R-N23133, 440R-N23134, 440R-N23135, 440R-N23135M, 440R-N23135S, 440R-N23213
Topic
Summary of Changes
Safety
Declaration of Conformity
Functional Description
Diagnostics
Safety Input
Reset
Wiring Examples
Circuit Diagram
Approximate Dimensions
Installation
Safety Specification
Technical Specifications
Summary of Changes
This publication contains the following new or updated information. This list
includes substantive updates only and is not intended to reflect all changes.
Translated versions are not always available for each revision.
Topic
Updated title of publication
Updated Declaration of Conformity section
Updated Positive Edge section
Updated Circuit Diagram section
Updated Safety Specification section
Safety
This device is intended to be part of the safety-related control system of a
machine.
Safety Notes
Before installation, a risk assessment must be performed to determine whether
the specifications of this device are suitable for all foreseeable operational and
environmental characteristics of the machine to which it is to be fitted. At regular
intervals during the life of the machine, check whether the characteristics
foreseen remain valid.
ATTENTION: Danger of serious injuries.
Misuse can result in malfunction.
• Only authorized and trained personnel must start up,
assemble, install, manipulate, or retrofit the device.
• Installation must be in accordance with these instructions.
• Do not defeat, tamper, remove, or bypass this unit.
Rockwell Automation cannot accept responsibility for failure of this device if the
Page
procedures given in these instructions are not followed or if it is used outside the
1
recommended specifications in these instructions.
1
1
IMPORTANT
The safety inputs of these products are described as
1
normally closed (N.C.), that is, with the guard closed,
1
actuator in place (where relevant) and the machine able to
be started. Exposure to shock and/or vibration in excess
2
of what is stated in IEC 60068 part: 2-6/7 must be avoided.
2
Adherence to the recommended inspection and
2
maintenance instructions forms part of the warranty.
2
3
Repair
3
3
3
ATTENTION: MSR127 safety relays are not repairable.
If there is any malfunction or damage, do not attempt to repair. The unit must be
replaced before machine operation is allowed.
Declaration of Conformity
Page
Rockwell Automation declares that all MSR127 safety relays are in
1
conformity with Directives 2014/30/EU, 2006/42/EC, 2011/65/EU as
1
specified in the Declaration of Conformity available from
2
rok.auto/certifications.
2
3
Functional Description
The unit is enabled once supply is powered up and the safety circuits are closed.
The PWR status indicator is on.
A valid reset operation activates the safety outputs. The CH1 and CH2 status
indicators of the output are lit. At demand of the safety function and if any fault,
the safety outputs are de-energized within the specified response time.
Fault Detection
If a fault occurs, the internal relay circuit forces the safety outputs off. One or both
output status indicators may be off. The PWR indicator may be flashing. Remove
the fault and cycle the safety input to re-enable the device. Cycling power to the
safety relay can also clear the fault condition.
Diagnostics
Auxiliary (N.C.) outputs 41...42 monitor the safety output state.
loading

Summary of Contents for Allen-Bradley MSR127

  • Page 1 Translated versions are not always available for each revision. Declaration of Conformity Topic Page Rockwell Automation declares that all MSR127 safety relays are in Updated title of publication conformity with Directives 2014/30/EU, 2006/42/EC, 2011/65/EU as Updated Declaration of Conformity section...
  • Page 2 MSR127 Minotaur Monitoring Safety Relays Installation Instructions Safety Input Wiring Examples The safety input can be single channel or dual channel. According to the wiring Figure 1 - Dual-channel Safety Gates, Monitored Manual Reset, inputs, cross-loop monitoring of the inputs is enabled or disabled. Cross­loop Monitored Output monitoring can be enabled for 2-channel safety inputs in 4­wire connection...
  • Page 3 Overvoltage category III, VDE 0110-1 Operating temperature -5…+55 °C (23…131 °F) Safety Specification Relative humidity All MSR127 safety relays can be used in safety circuits according to EN ISO 13849-1 Enclosure protection IP40 (NEMA 1) and IEC 61508/IEC 62061. Terminal protection...
  • Page 4 Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenkÖy, İstanbul, Tel: +90 (216) 5698400 EEE YÖnetmeliğine Uygundur Allen-Bradley, expanding human possibility, Minotaur, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.