control unit is a fire detection control unit manufactured in conformity with the EN.54.2 and EN.54.4 rules.
AM-8200
Technical features :
Multi-microprocessor system with 7" TFT display (800 x 480 with backlit ), 256 colors touch-screen with keyboard
simulation to program and configure the system and the following specific functions : Reset Delay, Silence
Buzzer , Silence/Restart Sounders, Reset, Evacuation.
Detection LINES:
2 analogue lines programmable to closed or open loop for the connection of the field elements
Each line can drive 159 sensors + 159 input and output modules
Max 4 loop each panel using the optional 2 loop LIB-8200 board.
Max 6 loop with the basic expansion box AM-8200BB
Max 6 loops using the AM-8200BB expansion box
Max 8 loop using the optional 2 loop LIB-8200 board LIB-8200 inside AM-8200BB expansion box
OPTION CARDS:
AM82-2S2C: 2 Serial ports+ 2 CanBus network
1 x RS.485 (optically isolated) to drive remote LCD repeaters and 1 x RS.232 (optically isolated) to connect a
o
serial printer
x Can-Bus lines to connect in closed loop ring a network of max 16 loop or 32 loop
2
o
POWER SUPPLY:
Input : 100
240Vac, 1,9° 50
÷
o
Voltage 27,6Vdc - 4A total.
o
Battery charger 27,5 Vdc – 1A (
o
User output 28Vdc (+3% +/ -18%) 3.5A,on board
o
OUTPUTS:
1 Supervised Sounder Output
o
1 General Alarm Output with contacts free from voltage / supervised Output (EOL 4
o
1 General Fault Output with contacts free from voltage / supervised Output (EOL 4
o
Mechanics
The control unit mechanics is suitable for wall installations.
For cabinet sizes refer to the below drawing "AM-8200 dimensions"
Protection grade : IP 30
o
Operation temperature : -5 °C to +40 °C
o
Stockage temperature
o
Weight: 7 Kg (AM-8200)
o
Weight: 5 Kg (AM-8200BB)
o
Main Functions
3 password levels (Operator - Maintenance – Configuration)
4 total access levels in conformity with the EN.54 rules
Programmable text : point description through 32 characters; zone description through 32 characters
500 physical zones and 400 logical groups in stand-alone or 16 loop network configuration
CBE Control Equations (Control-by event) for activation with logical operators (And, Or, Xor , etc.).
History Event file with the last 2000 events in non-volatile memory (20.000 in the Network master LCD)
Real time clock
Line self-programming with automatic recognition of the type of the connected devices.
Automatic recognition of points having the same address.
Decision algorithms for the alarm and fault criteria.
Automatic sensitivity change Daytime /Night.
Signaling of need for sensor cleaning
Signaling of poor sensor sensitivity
Programmable alarm threshold for sensors
Pre-defined software function programming for the various devices used
Walk-Test function for zones.
AM-8200
AM8200_manu-inst
GENERAL DESCRIPTION
÷60Hz
with temperature compensation
to power external loads such as sirens, bells, etc
: -10 °C to +50 °C
Installation Manual
Doc. M-162.2-AM8200-ENG Rev A.2
).