Profinet (Lan) X1; Profinet (Lan) X2 - Siemens SIMATIC HMI Unified Comfort MTP700 Operating Instructions Manual

Hide thumbs Also See for SIMATIC HMI Unified Comfort MTP700:
Table of Contents
8.9.3

PROFINET (LAN) X1

PROFINET (LAN) 10/100 Mbps, RJ45 socket
Pin
1
2
3
4
5
6
7
8
8.9.4

PROFINET (LAN) X2

PROFINET (LAN) 10/100/1000 Mbps, RJ45 socket
Pin
1
2
3
4
5
6
7
8
Unified Comfort Panels
Operating Instructions, 03/2020, A5E46641217-AA
Name
Tx+
Tx–
Rx+
NC
NC
Rx–
NC
NC
Name
D1+
D1–
D2+
D3+
D3-
D2-
D4+
D4-
Meaning
Data output +
Data output -
Data input +
Not assigned
Not assigned
Data input -
Not assigned
Not assigned
Meaning
Bi-directional data 1+
Bi-directional data 1-
Bi-directional data 2+
Bi-directional data 3+
Bi-directional data 3-
Bi-directional data 2-
Bi-directional data 4+
Bi-directional data 4-
Technical information
8.9 Description of the interfaces
161

Hide quick links:

Table of Contents
loading

Table of Contents