Operating And Display Components; Reset Button - Bosch rexroth IndraControl VAU 02.1 Operating Instructions Manual

Table of Contents
IndraControl VAU 02.1 Uninterruptible
Power Supply
The UPS can only supply one control cabinet with voltage when the
voltage supply fails.

12.1 Operating and display components

The LEDs of the status and error display as well as the "Reset" button are loca-
ted on the front panel.
Fig. 12-1: Control and display components
"Reset" button
Diagnostic LEDs
– UPS OK
– 24 V In
– Batt. OK
– Batt. Charge

12.1.1 Reset button

If the IPC does not work properly anymore and if it cannot be switched off or
restarted, use the "Reset" button of the UPS to disconnect the IPC from voltage
and to execute a reboot.
If the "Reset" button is pressed, the output voltage is disconnected (0 V). If an
input voltage is present at the UPS while pressing the "Reset" button, the out-
put voltage is switched on again after four seconds (24 V).
Device description
R911384727_Edition 03 Bosch Rexroth AG
21/31
Table of Contents