Emerson Rosemount Analytical HART SMART 5081C-HT Instruction Sheet

Remote controlled two-wire conductivity transmitter

Quick Links

Instruction Sheet
LIQ_MAN_ABR_5081C-HT/Rev.G
ESSENTIAL INSTRUCTIONS
Read this page before proceeding!
Your purchase from Rosemount Analytical, Inc. has resulted in one of the finest instruments available for your particular
application. These instruments have been designed, and tested to meet many national and international standards.
Experience indicates that its performance is directly related to the quality of the installation and knowledge of the user in
operating and maintaining the instrument. To ensure their continued operation to the design specifications, personnel
should read this manual thoroughly before proceeding with installation, commissioning, operation, and maintenance of
this instrument. If this equipment is used in a manner not specified by the manufacturer, the protection provided by it
against hazards may be impaired.
• Failure to follow the proper instructions may cause any one of the following situations to occur: Loss of life; personal
injury; property damage; damage to this instrument; and warranty invalidation.
• Ensure that you have received the correct model and options from your purchase order. Verify that this manual
covers your model and options. If not, call 1-800-854-8257 or 949-757-8500 to request correct manual.
• For clarification of instructions, contact your Rosemount representative.
• Follow all warnings, cautions, and instructions marked on and supplied with the product.
• Use only qualified personnel to install, operate, update, program and maintain the product.
• Educate your personnel in the proper installation, operation, and maintenance of the product.
• Install equipment as specified in the Installation section of this manual. Follow appropriate local and national codes.
Only connect the product to electrical and pressure sources specified in this manual.
• Use only factory documented components for repair. Tampering or unauthorized substitution of parts and
procedures can affect the performance and cause unsafe operation of your process.
• All equipment doors must be closed and protective covers must be in place unless qualified personnel are
performing maintenance.
• If this equipment is used in a manner not specified by the manufacturer, the protection provided by it against
hazards may be impaired.
WARNING
Substitution of components may impair Intrinsic Safety or
suitability for division 2.
WARNING
do not remove or replace while circuit is live unless area is
known to be non-hazardous.
WARNING
explosion Hazard - do not disconnect equipment unless area
is known to be non-hazardous.
WARNING
To prevent ignition of flammable or combustible atmos-
pheres, disconnect power before servicing or understand and
adhere to the manufacturer's live maintenance procedures.
SpeCIAl CoNdITIoN FoR INTRINSICAlly SAFe USe
The 5081 enclosure is made of aluminum alloy and given a
protective polyurethane finish; however, care must be taken
to protect it from impact, abrasion or friction with other
metal surfaces if located in zone 0.
WARNING
If a Model 475 Universal Hart® Communicator is used with
these transmitters, the software within the Model 475 may
require modification.
If a software modification is required, please contact your
local Fisher-Rosemount Service Group or National Response
Center at 1-800-654-7768.
5081C-HT
January 2015
Table of Contents
loading

Summary of Contents for Emerson Rosemount Analytical HART SMART 5081C-HT

  • Page 1 Instruction Sheet 5081C-HT LIQ_MAN_ABR_5081C-HT/Rev.G January 2015 ESSENTIAL INSTRUCTIONS Read this page before proceeding! Your purchase from Rosemount Analytical, Inc. has resulted in one of the finest instruments available for your particular application. These instruments have been designed, and tested to meet many national and international standards. Experience indicates that its performance is directly related to the quality of the installation and knowledge of the user in operating and maintaining the instrument.
  • Page 2: Physical Specifications

    5081C-HT Instruction Sheet January 2015 LIQ_MAN_ABR_5081C-HT/Rev.G Specifications explosion-proof: Class I, Div. 1, Groups B-D Class II, Div. 1, Groups E-G pHySICAl SpeCIFICATIoNS Class III, Div. 1 Housing: Cast aluminum with epoxy coating. Type 4X Class I, Groups B-D (IP65). Neoprene O-ring cover seals. 160.5 mm x 175.3 mm Class II, Groups E-G x 161.3 mm (6.3 in.
  • Page 3: Infrared Remote Controller

    Instruction Sheet 5081C-HT LIQ_MAN_ABR_5081C-HT/Rev.G January 2015 INFRARed ReMoTe CoNTRolleR 3. Use the editing keys to scroll through lists of allowed settings or to change a numerical setting to the 1. Pressing a menu key allows the user access to desired value. calibrate, program, or diagnostic menus.
  • Page 4 5081C-HT Instruction Sheet January 2015 LIQ_MAN_ABR_5081C-HT/Rev.G FIGURe 2. Menu Tree CALIbrAtE SEnSOr 0 tE M P AdJ CAlIbRATIoN Mtr CAL CELL tE M P OUtPUt OutPut tE M P dISPLAY process display pRoGRAM HArt SEtUP 5081C-HT dEFAULT Process Display Screen AbS C 0 air 5000...
  • Page 5: Asset Management Solutions (Ams)

    Instruction Sheet 5081C-HT LIQ_MAN_ABR_5081C-HT/Rev.G January 2015 ASSeT MANAGeMeNT SolUTIoNS (AMS) Rosemount Analytical AMS windows provide access to all and can reconfigure the transmitter from anywhere in the transmitter measurement and configuration variables. The plant. The figures below show two of the many configura- user can read raw data, final data, and program settings tion and measurement screens available using HART AMS.
  • Page 6 5081C-HT Instruction Sheet January 2015 LIQ_MAN_ABR_5081C-HT/Rev.G TAble 1. 5081C-HT default Settings VARIAble NAMe MNeMoNIC FACToRy SeTTINGS CUSToMeR SeTTINGS program Menu output – ___________ Output 4 mA 0 µS ___________ 4 mA 20 mA 20 mS ___________ 20 mA Hold 21 mA ___________ hold Fault...
  • Page 7: Power Wiring

    Instruction Sheet 5081C-HT LIQ_MAN_ABR_5081C-HT/Rev.G January 2015 Wiring Wire sensor as shown below in Figure 5. Keep sensor wiring separate from power wiring. For best EMI/RFI pro- tection, use shielded output signal cable in an earth- grounded metal conduit. Refer to the sensor instruction manual for more details.
  • Page 8: Installation

    5081C-HT Instruction Sheet January 2015 LIQ_MAN_ABR_5081C-HT/Rev.G Installation UNpACKING ANd INSpeCTIoN INSTAllATIoN See Figure 7 Inspect the shipping container. If it is damaged, contact 1. Although the analyzer is suitable for outdoor use, do the shipper immediately for instructions. Save the box. If not install it in direct sunlight or in areas of extreme there is no apparent damage, unpack the container.
  • Page 9 Instruction Sheet 5081C-HT LIQ_MAN_ABR_5081C-HT/Rev.G January 2015 FIGURe 8. ATeX label Information ® ROSEMOUNT ANALYTICAL II 1 G 1180 MODEL 5081-C-HT-73 IECExBAS09.0159X Baseefa03ATEX0099X Ex ia IIC T4 Ga Tamb = -20°C TO +65°C I.S. SUPPLY Ui = 30 VDC Ii = 200 mA Pi = 0.9 W Ci = 0 µF Li = 0 µH...
  • Page 10 5081C-HT Instruction Sheet January 2015 LIQ_MAN_ABR_5081C-HT/Rev.G Figure 9. FMRC explosion-proof Installation...
  • Page 11 Instruction Sheet 5081C-HT LIQ_MAN_ABR_5081C-HT/Rev.G January 2015 Figure 10. FM Hazardous Area Approval label...
  • Page 12 5081C-HT Instruction Sheet January 2015 LIQ_MAN_ABR_5081C-HT/Rev.G Figure 11. FM Intrinsically Safe Installation...
  • Page 13 Instruction Sheet 5081C-HT LIQ_MAN_ABR_5081C-HT/Rev.G January 2015 Figure 12. CSA Hazardous Area Approval label...
  • Page 14 5081C-HT Instruction Sheet January 2015 LIQ_MAN_ABR_5081C-HT/Rev.G Figure 13. CSA Intrinsically Safe Installation...
  • Page 15: Quick Start

    Instruction Sheet 5081C-HT LIQ_MAN_ABR_5081C-HT/Rev.G January 2015 Engineering Specifications qUICK-START temperature compensation: lineAr (linear), n SAlt (neutral salt), CatIon (cation conductivity), or none 1. On the Remote, press PROG, NEXT, NEXT, ENTER. (raw or uncompensated conductivity). Press ENTER. If 2. Use the arrow buttons to select Conduc you are in lineAR mode, you can now enter a (conductivity), rStvty (resistivity), or CuSt (custom particular temperature slope (default is 2%/degC),...
  • Page 16 ©2015 Rosemount Analytical, Inc. All rights reserved. The Emerson logo is a trademark and service mark of Emerson Electric Co. Brand name is a mark of one of the Emerson Process Management family of companies. All other marks are the property of their respective owners.

Table of Contents