Pressure transmitter; single-use process connector (12 pages)
Summary of Contents for Emerson Micro Motion 5700
Page 1
ATEX Installation Instructions EB-20025742 Rev. AC December 2015 Micro Motion ® Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc...
Page 2
5700 ATEX Installation Instructions EB-20025742 Rev. AC December 2015 Manufactured and submitted for examination Micro Motion, Inc. Address Boulder, Co. 80301, USA Basis for examination Annex II of Directive 2014/34/EU Subject: Equipment type Transmitter type 5700I1***VA*** EN 60079-0:2012+A11:2013 General requirements EN 60079-11:2012 Type of protection ´i´...
5700 ATEX Installation Instructions December 2015 EB-20025742 Rev. AC Model Designation Transmitter type 5700*1******** Instead of the *** in the complete denomination letters and numerals will be inserted which characterize the following variations: Type 5 7 0 0 * 1 * * * * * * * * Options without influence on explosion protection Approval VA = 5700I =...
Page 4
5700 ATEX Installation Instructions EB-20025742 Rev. AC December 2015 Description The transmitter is, in combination with a sensor, used for measurement of mass flow and data transmission. The electrical circuitry of the transmitters is mounted inside a metal enclosure which is divided into three compartments.
Page 5
5700 ATEX Installation Instructions December 2015 EB-20025742 Rev. AC Parameters Mains circuits: (J1, terminal 1 - 2) 3.1.1 for type 5700*1*(A,E,N)****** voltage AC/DC 18 - 240 V + 10 % max. voltage AC/DC (J6, terminal 1 - 2) 3.1.2 for type 5700*1*C****** voltage AC/DC 18 - 240 V + 10 %...
Page 6
5700 ATEX Installation Instructions EB-20025742 Rev. AC December 2015 Parameters (continued) 3.3.1.1 for type 5700*1*E******(J3,terminals 1-2 FF) for the connection of a FIELDBUS circuit in accordance with FISCO model, Annex G of EN 60079-11:2012 voltage current power 5,32 effective internal inductance μH effective internal capacitance 0,27...
Page 7
5700 ATEX Installation Instructions December 2015 EB-20025742 Rev. AC Parameters (continued) Sensor circuits for type 5700(C or I)1********; “ib” 3.5.1 Drive circuit; (J2 in J-box, DR+ BRN; DR- RED) voltage 10,5 current; instantaneous 1,06 current; steady state 0,272 power 2,13 ...
5700 ATEX Installation Instructions EB-20025742 Rev. AC December 2015 Parameters (continued) 3.5.3 Temperature circuit (J1 in J-box, RTD+ VIO; RTD- ORA; RTD-SIG YEL) voltage 17,3 current 19,26 power 83,3 for group IIC max. external capacitance max. external inductance 95,8 max. external induct/resist Lo/Ro 0,42 mH/...
Page 9
5700 ATEX Installation Instructions December 2015 EB-20025742 Rev. AC Marking Type 5700*1******** -40°C to +65°C For BVS 14 ATEX E 055 X: type type of protection Model 5700I12A*VA*** II 3G Ex nA nC IIB+H T5 Gc (Ex nA nC) II 3D Ex tc IIIC T75°C Dc IP66/IP67 Model 5700I1(3,5)A*VA*** II 3G Ex nA nC IIC T5 Gc (Ex nA nC)
Page 10
5700 ATEX Installation Instructions EB-20025742 Rev. AC December 2015 Marking (Continued) For BVS 14 ATEX E 175 X: type type of protection Model 5700(R,C)12A*VA*** 2460 II 3 (2)G Ex nA nC [ib Gb]IIB+H T5 Gc (Ex nA nC) II 3 (2)D Ex tc [ib Db] IIIC T75°C Dc IP66/IP67 Model 5700(R,C)1(3,5)A*VA*** 2460 (Ex nA nC)
Page 11
5700 ATEX Installation Instructions December 2015 EB-20025742 Rev. AC Special conditions for safe use / Installation instructions For the application of the transmitter in an ambient temperature of less than - 20°C suitable cable and cable entries or conduit entries certified for this condition shall be used.